Cisco Systems 5709 Manual De Usuario

Descargar
Página de 247
NetXtreme II
User Guide
January 2010
Bro a d c o m   C o rp o r a ti o n
Page 112
Installing the NDIS2 Driver Software for Use on MS-DOS Platforms
Document
ENGSRVT52-CDUM100-R
lastdrive=z
I
NSTALLING
 
THE
 DOS NDIS2 D
RIVER
 S
OFTWARE
 
ON
 
THE
 H
ARD
 D
ISK
To install the DOS NDIS2 Driver Software on the hard disk
1. Verify that the system has Microsoft LAN Manager 2.2 installed, with a protocol such as NetBEUI configured. 
2. Create a folder on your hard disk to store the NDIS 2.01 driver. 
Example: C:\LANMAN 
3. Copy the BXND20X.dos file to this folder. 
Edit the Config.sys file by adding the following lines: 
DEVICE = C:\LANMAN\PROTMAN.DOS 
DEVICE = C:\LANMAN\BXND20X.DOS
DEVICE = C:\LANMAN\NETBEUI.DOS
4. Edit the Autoexec.bat file by adding the following lines: 
C:\ LANMAN\NETBIND.EXE
C:\LANMAN\NET START WORKSTATION 
C:\LANMAN\NET USE drive letter: \\server name\resource name
5. Edit the Protocol.ini file (located in C:\LANMAN) to configure the driver to bind with NetBEUI or any other protocols. 
Example: 
[PROTOCOL MANAGER]
DriverName = PROTMAN$ 
[NETBEUI_XIF]
DriverName = netbeui$
BINDINGS = BXND20X
[BXND20X]
DriverName = "BXND20X$" 
6. Restart the computer to complete the installation. 
NOTE: The driver loads during system configuration and displays the Broadcom banner, controller name, MAC
address, IRQ number, detected line speed, and the controller BusNum and DevNum. If the driver fails to load, an
initialization fail message is displayed.