Integrated L-Band Up/Dn Converter
 
LT3600
 
CG-1309
 
 
 
 
 Page 20 
 
SECTION 4 
Serial Command Set 
 
4.0 GENERAL 
The standard Up/Dn Converter is controlled via a rear panel serial link (RS-422/485)(Reconfigurable 
to RS-232). With the front panel control, a user can operate the L-Band Up/Dn Converter from its 
front panel as well as from the serial link. This section describes the format for the ASCII serial 
control as well as front panel operation. 
 
Note: Some commands and status strings have been changed as of Software Release v7.70 (main 
board) and v5.20 (front panel).  Units marked with “Rev A” on the rear panel support the new 
protocol. 
 
4.1 LT-3600 SERIAL INTERFACE 
The serial interface format to the Up/Dn Converter for RS-422 is identical to the RS-485 format 
except that under RS-485, the format includes an address field (aa in the format below). 
 
4.2 COMMUNICATION PROTOCOL 
 
Baud Rate: 
9600 
Parity:  
None 
Data Bits: 
Eight 
Start Bits: 
One 
Stop Bits: 
One 
 
4.2.1 General Data Format 
{aaCND…} 
 
Where: 
 
= Start byte 
 
aa 
= 2 character address (00 to 50, remote interface only) 
 
= 1 character, either C (Command) or S (Status) 
 
= 1 number 0 to 9, A,B,C Command or Status Number 
 
= 1 or more Data characters (depending on command) 
 
= Stop byte 
 
Note: The address is only used in the RS-485 mode when having several addressable units 
communicating with one station.