Serial Configuration
143
Serial Configuration
SYSGEN - Use the ASYNC_PRT macro name.
CHAR8 SYSGEN modifier is highly recommended.
SPOOLCOM - DEVTYPE should be blank.
NOTE: DEVSUBTYPE SYSGEN modifier must be set to 32.
ETX/ACK - Protocol is not recommended.
CURRENT LOOP - Supported only when using a Current Loop to 
RS232 adapter, TCL2 (P/N 50069). Flow control is provide by XON/
XOFF only. On the printer set the DTR option to True. Note that any 
other setting can cause Framing and Parity errors.
RS232 - Supports both XON/XOFF and DTR. Both XON/XOFF and 
DTR are used for flow control only, and do not provide any status back 
to the host other than printer ready, or not ready. For a complete list of 
attributes for serial printers, refer to the System Generation manual for 
Terminals and Printers (P/N 107875).
RS422 - Supported by both Compaq hosts and printers. However, the 
RS422 cables provided by Compaq are not suitable for use with these 
printers. Thus, a custom cable must be used if you are using the RS422 
protocol. (See 
 for pin assignments for a typical RS422 
connection.) Flow control is provided by XON/XOFF only. 
Figure 14. RS-422 Pin Assignments
TXD+
25
17
RXD+
TXD-
18
15
RXD-
RXD+
10
25
TXD+
RXD-
11
19
TXD-
GND
1
1
GND
(optional)
GND
7
Signal GND
RTS
4
CTS
5
DCD
8
DTR
20
DSR
6