Cognitive Solutions A799 Manual De Usuario

Descargar
Página de 142
Chapter 4: Programming Commands
 111
Revision D 12/09
A799-PG00001D
User data storage
Write to user data storage
ASCII 
ESC ‘ m a0 a1 a2 d1 ... dm 
Hexadecimal  1B 27 m a0 a1 a2 d1 ... dm 
Decimal 
27 39 m a0 a1 a2 d1 ... dm
Value of m: 
0 – 255
Writes m bytes of data to the user data storage flash page at the address specified. The printer waits for m bytes of data 
following the 3-byte address, addr.
If any of the memory locations addressed by this command are not currently erased, the command is not executed.
Related information
Result of this write is returned in bit 2 of response to transmit status command 1D 72, = 4.
Read from user data storage
ASCII 
ESC 4 m a0 a1 a2 
Hexadecimal  1B 34 m a0 a1 a2 
Decimal 
27 52 m a0 a1 a2
Value of m: 
0 – 255
Reads m bytes of data from the user data storage flash page at the address specified.
Read from non-volatile memory
ASCII 
ESC j k 
Hexadecimal  1B 6A k 
Decimal 
27 106 k
Range of k: 
20 – 63 (decimal)
Reads a two-byte word from location k in the history EEROM. The printer returns the word at the next available 
opportunity.
Related information:
This is ignored in LEGACY emulation and the parameter byte goes into the print buffer.
Write to non-volatile memory (NVRAM)
ASCII 
ESC s nnk 
Hexadecimal  1B 73 nnk 
Decimal 
27 115  nnk
Value of n1: 
1
st
 Byte
Value of n2: 
2
nd
 Byte
Range of k: 
20 – 63 (decimal locations)
Writes the two-byte word, nn2, to location k in history EEROM.
Related information:
This is ignored in LEGACY emulation and the parameter bytes go into the print buffer.