Cash drawer status (n = 2 or n = 50)
Bit  Off/On  Hex  Decimal  Status for transmit status
Off 
00 
One or both cash drawers  
 
 
 
 
open. 
 
On 
01 
Both cash drawers closed.
Off 
00 
One or both cash drawers  
 
 
 
 
open. 
 
On 
02 
Both cash drawers closed.
– 
– 
– 
Undefined
– 
– 
– 
Undefined
Off 
00 
Not used. Fixed to off.
– 
– 
– 
Undefined.
– 
– 
– 
Undefined.
Off 
00 
Not used. Fixed to off.
Flash memory user sector status (n = 4 or n = 52)
Bit  Off/On  Hex  Decimal  Status for transmit status
– 
– 
– 
Undefined. Fixed to off.
– 
– 
– 
Undefined. Fixed to off.
Off 
00 
User data storage write successful
 
On 
04 
User data storage write failed, specified area not erased.
Off 
00 
Flash logo area adequate, definition stored
 
On 
08 
Flash logo area not adequate
Off 
00 
Not used. Fixed to off.
Off 
00 
00 
No thermal user-defined characters 
 
 
 
 
written to flash.
 
On 
20 
32 
Thermal user-defined characters written to flash.
Off 
00 
Not used. Fixed to off.
– 
– 
– 
Undefined.
Exceptions
When n is out of the specified range, the command is ignored.
Send printer software version
ASCII 
AX V 
Hexadecimal  1F 56 
Decimal 
31 86
The printer returns 8 bytes containing the boot and flash software version. The first 4 bytes returned are an ASCII string for 
the boot version. 
The second 4 bytes are an ASCII string for the flash version. Example: For 1.234.56 (8 bytes), the boot version is 1.23 and 
the flash version is 4.56.