Description 
 
3.4 Function 
SIMATIC Rack PC IL 43 
Operating Instructions, Edition 09/2005, A5E00432875-01 
3-3
 
3.4 
3.4 
Function 
 
• 
Integrated, assigned monitoring functions 
– 
Fan speed (CPU, power supply and front fan) 
– 
Temperature (case, processor) 
– 
Program execution (watchdog) 
• 
RAID1 for automatic data mirroring of two serial ATA hard drives 
• 
Intel Hyper Treading (HT) processor technology 
Thanks to efficient resource utilization, the Intel Pentium 4 with hyper threading (HT) 
technology can process two tasks (threads) simultaneously, as in this case it behaves like 
two virtual processors. The following requirements must be met by the system:  
• 
Processor with HT technology 
• 
Activated HT technology support in system BIOS 
• 
An HT technology capable, optimized operating system 
• 
Customer applications optimized for HT technology 
3.5 
3.5 
Features 
 
General features 
Installation design 
• 
19” rack, 4 HE 
• 
Robust full metal rack design case, lacquered outside and 
coated inside 
• 
Prepared for mounting telescopic rails 
• 
Horizontal and vertical installation is possible 
• 
Tower installation by means of tower kit 
• 
Lockable front cover as access protection 
Enclosure 
• 
Dust protection by means of overpressure ventilation using 
bearing seated front fan through filter 
• 
Card retainer for reliable operation of PC modules under 
vibration and shock conditions 
Drive bays 
• 
Front: 3 x 5.25" and 2 x 3.5" 
• 
Internal: 2x 3.5" 
Slots for expansion cards 
• 
4 x PCI long 
• 
2 x PCIe x1 long 
• 
1 x PCIe x16 long 
Graphics 
• 
Onboard Intel® GMA950 graphics controller 
Chipset integrated 2-D and 3-D engine,  
up to 2048 x 1536 at 75 Hz 
Dynamic Video Memory Technology  
up to 800 x 600 at 120 Hz / 32 bit color 
up to 1280x1024 at 100 Hz / 32 bit color 
up to 2048 x1536 at 75 Hz / 16 bit colors