CyberPower Systems BR650ELCD Prospecto

Descargar
Página de 2
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
BR450ELCD/BR650ELCD/BR850ELCD 
User’s Manual 
K01-0000056-00
 
 
SAFETY WARNINGS   
(SAVE THESE INSTRUCTIONS)
 
This manual contains important safety instructions. Please read and follow all instructions carefully 
during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, 
install, or operate your UPS. 
 
This equipment can be operated by any individuals with no previous training. 
 
The socket-outlet shall be installed near the equipment and easily accessible. 
 
During the installation of this equipment it should be assured that the sum of the leakage currents of the 
UPS and the connected loads does not exceed 3.5mA. 
 
Attention, hazardous through electric shock. Also with disconnection of this unit from the mains, 
hazardous voltage still may be accessible through supply from battery. The battery supply should be 
therefore disconnected in the plus and minus pole at the quick connectors of the battery when 
maintenance or service work inside the UPS is necessary. 
 
Do not dispose of batteries in a fire, the battery may explode. 
 
Do not open or mutilate the battery or batteries, released electrolyte is harmful to the skin and eyes. 
 
 
INSTALLING YOUR UPS SYSTEM   
 
UNPACKING 
 
Inspect the UPS upon receipt. The box should contain the following: 
(1)UPS Unit
¯1; (1)Phone Line¯1;(3)USB Cable¯1;(4)User Manual¯1;(5)Management software 
Disk
¯1;(6)Green Power Technology description¯1;(7)Battery Charger¯1;(8)Cable Collector¯1 
 
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 
 
1.  Insure that the equipment plugged into the battery power-supplied outlets does not exceed the UPS 
unit’s rated capacity (450VA/270W for BR450ELCD, 650VA/390W for BR650ELCD, 850VA/510W for 
BR850ELCD). If rated unit capacities are exceeded, an overload condition may occur and cause the 
UPS unit to shut down or the fuse blow. 
 
2.  If the power requirements of your equipment are listed in units other than Volt-Amps (VA), convert 
Watts (W) or Amps (A) into VA by doing the calculations below. Note: The below equation only 
calculates the maximum amount of VA that the equipment can use, not what is typically used by the 
equipment at any one time. Users should expect usage requirements to be approximately 60% of 
below value. 
 
TO ESTIMATE POWER REQUIREMENTS 
 
1.               Watts (W) x 1.67 =         VA or               Amps (A) x 230 =        VA 
 
2. Add the totals up for all pieces of equipment and multiply this total by 0.6 to calculate actual 
requirements. There are many factors that can affect the amount of power that your computer system 
will require.
 
Suggest the total load to be placed on the battery-powered outlets should not exceed 
80% of the unit’s capacity. 
 
HARDWARE INSTALLATION GUIDE 
 
Before installation, please read and understand the following instructions: 
 
1. Placement 
The UPS must be installed in a protected environment away from heat- emitting appliances such 
as a radiator or heat register. Do not install this product where excessive moisture is present. 
 
 
 
2. Ventilation 
The location should provide adequate air flow around the UPS with one inch minimum clearance 
on all sides for proper ventilation. 
3. 
Charge the Battery 
Your new UPS may be used immediately upon receipt. However charge loss may occur during 
shipping and storage. So charging the battery for at least 8 hours is recommended to insure that 
the battery is fully charged. (To recharge the battery, simply leave the unit plugged into an AC 
outlet.)  
This UPS can be charged even when UPS is not turn on. 
 
4. Connect 
to 
AC 
Use power cord to connect   
the UPS to a wall outlet. Please avoid       
using extension cords and adapter   
plugs. (To maintain optimal battery   
charge, leave the UPS plugged in at   
all times.)     
 
5. 
Connect the Load 
Connect the equipment to your UPS 
  outlets. The IEC power cord coming   
with the unit are used to connect your   
computer and monitor to the UPS.   
Items such as copiers, laser   
printers, vacuums, space heaters,   
or other large electrical devices   
SHOULD NOT be connected to the   
UPS.
 Please make sure that the total   
loads of your equipments are less than the maximum total power load of your UPS. 
 
6. 
Connect to Computer 
Install your software and accessories. To use the software, simply use the USB cable to connect 
the UPS unit and your computer.   
             
 
BASIC OPERATION 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
     
 
 
 
1. Power On/Off Switch 
      Press the power switch to turn the UPS ON or OFF. 
 
2. LCD Function Selected Switch 
 
  Press the LCD function selected switch to know the UPS status. 
 
3. LCD Display 
    
The LCD will display the UPS status including input voltage, output voltage, runtime, percentage of 
load and battery…etc.   
 
4. Communication Protection Ports RJ11/RJ45 
     Communication protection ports will protect any standard modem, fax, telephone line, or network 
cable from surge and spikes. 
 
5. Battery Charger port 
    
Charge external AA/AAA battery via battery charger port with battery charger. 
 
6. AC outlet 
    The UPS provides 3 outlets for connected equipment to insure temporary uninterrupted operation 
during a power failure and against surges and spikes and another 3 outlets against surges and spikes 
only. 
 
7. USB Port to PC
 
      This port allows connection and communication  
  from the USB port on the computer to the UPS   
  unit. The UPS communicates its status to the   
 PowerPanel
®
 Personal Edition software. This      
interface is also compatible with the UPS service   
provided by Windows NT, Windows 2000,   
Windows XP, Windows Vista. Mac OSX, Linux. 
 
8. Input Circuit Breaker 
The Circuit Breaker provides optimal overload protection. 
 
9 Power on LED 
The power on LED lights up when the UPS is ON. 
 
10 Cable Collector 
Collect the cables connected from the AC outlets in the cable collector. 
 
11 Battery Charger 
Put external AA/AAA batteries into the battery charger for charge.