SmartSwitch ATM User Guide   3-9
PNNI Routing
Managing Parallel PNNI Links  
3.3
MANAGING PARALLEL PNNI LINKS
ATM SmartSwitches can be connected by more than one physical link. PNNI treats these connections as parallel 
physical links. By default, parallel links are considered to have equal capabilities with regard to call set ups. 
For example, if a second link is added between switch SWA3 and switch SWB3 (from the example above), this parallel 
link can be seen using the 
show pnnilink
 command.
SWA3 # show pnnilink
Num(ALL)                                  :
Num  Port     Node   Remote Node     Hello State    Link Type
     Number   Index  IP Addr
===========================================================================
1    7A1          1  206.61.237.20   2WayInside     Lowest Level Horizontal Link
2    7A3          1  206.61.237.19   2WayInside     Lowest Level Horizontal Link
3    7B1          1  206.61.237.23   CommonOut      Outside and Uplink
4    7B2          1  206.61.237.23   CommonOut      Outside and Uplink           
— Second physical link to B3
5    --           2  N/A             2WayInside     Horizontal Link to/from LGN
6    --           2  N/A             2WayInside     Horizontal Link to/from LGN  
— Second logical link to B3
SWA3 #
You can adjust the advertised capabilities of each link (on a per-port, per-service class basis) by changing the link’s 
administrative weights. Use the 
show pnniinterface
 command to view the current administrative weights. For 
example:
SmartSwitch # show pnniinterface
PortNumber(ALL)                           :
Port       Admin Wt    Admin Wt    Admin Wt    Admin Wt    Admin Wt  Aggregation
Number       CBR         RTVBR      NRTVBR       ABR          UBR       Token
================================================================================
CPU            5040        5040        5040        5040        5040           0
CPU.1          5040        5040        5040        5040        5040           0
7A1            5040        5040        5040        5040        5040           0
7A2            5040        5040        5040        5040        5040           0
7A3            5040        5040        5040        5040        5040           0
7A4            5040        5040        5040        5040        5040           0
7B1            5040        5040        5040        5040        5040           1
7B2            5040        5040        5040        5040        5040           0
7B3            5040        5040        5040        5040        5040           0
SmartSwitch #
A link’s administrative weight defines its desirability to the PNNI routing service when setting up a call of a particular 
class of service. The lower the numerical value of the administrative weight, the more desirable the route. For example, 
a route with administrative weight 200 for a particular class of service is considered a better route than one with the 
default weight of 5040 for that service. As a result, the administrative weight provides a quantitative way to control 
which routes are favored for call set up with regard to service class. 
The ability to control the PNNI routing service in this fashion allows for parallel routes to be weighted such that one 
link is designated as the favored for a particular service class, while a parallel link can be designated as the favored 
route for a different service class.