Casio C6800IA48FPD Manual De Usuario

Descargar
Página de 64
Voltages that present a shock hazard may exist on Power over Ethernet (PoE) circuits if interconnections
are made using uninsulated exposed metal contacts, conductors, or terminals. Avoid using such
interconnection methods, unless the exposed metal parts are located within a restricted access location
and users and service people who are authorized within the restricted access location are made aware of
the hazard. A restricted access area can be accessed only through the use of a special tool, lock and key
or other means of security. Statement 1072
Warning
No user-serviceable parts inside. Do not open. Statement 1073
Warning
Installation of the equipment must comply with local and national electrical codes. Statement 1074
Warning
To prevent airflow restriction, allow clearance around the ventilation openings to be at least: 3 inches (7.6
cm). Statement 1076
Warning
Hot surface. Statement 1079
Warning
Tools and Equipment
Obtain these necessary tools and equipment:
• A number-2 Phillips screwdriver to rack-mount the switch.
Installation Guidelines
When determining where to install the switch, verify that these guidelines are met:
• Clearance to the switch front and rear panel meets these conditions:
◦Front-panel LEDs can be easily read.
◦Access to ports is sufficient for unrestricted cabling.
◦AC power cord can reach from the AC power outlet to the connector on the switch rear panel.
◦Access to the rear of the rack is sufficient for connecting FlexStack cables to stacked switches, or
connecting the optional Cisco Redundant Power Supply (RPS) 2300.
• Cabling is away from sources of electrical noise, such as radios, power lines, and fluorescent lighting
fixtures. Make sure that the cabling is safely away from other devices that might damage the cables.
• Airflow around the switch and through the vents is unrestricted.
   Catalyst 6800IA Switch Hardware Installation Guide
18
OL-30278-01   
Switch Installation
Tools and Equipment