Chapter 2      Cabling and Troubleshooting the CSS
Troubleshooting the CSS Hardware Components
2-42
Cisco 11500 Series Content Services Switch Hardware Installation Guide
78-13884-06
Troubleshooting the Console Interface
 lists common communications problems that may exist between the 
CSS and a console. Ensure the console settings are configured to:
Baud Rate - 9600
Data Bits - 8
Parity - none
Stop Bits -1
Flow Control - none
For information on console cable pinouts, refer to Appendix B,  
.
Table 2-13 Troubleshooting the Console Interface
Possible Problem
Recommended Action
Nothing appears on the screen.
Ensure that the RS-232 cable is 
securely connected to the console port.
Characters appear on the screen, but 
are garbled.
Verify that the CSS and the console 
settings match with respect to baud 
rate, data bits, stop bits, and parity.
Abbreviated input is used, but pressing 
the tab key does not enter the command 
you want.
Ensure that you enter a sufficient 
number of characters for the CSS to 
distinguish between different 
commands and options.
Random characters are lost.
Set the flow command on the console 
to XON/XOFF.