3com 1000 Manual De Usuario

Descargar
Página de 152
Using the Switch
C-3
Try accessing the device through a different port. If 
you can now access the device, a problem with the 
original port is indicated. Re-examine the connec-
tions and cabling.
There may be a network problem preventing you 
accessing the device over the network. Try access-
ing the device through the console port.
You forget your password and cannot log in:
If you are not one of the default users (monitor, 
manager or security), another user having ‘security’ 
access level can log in, delete your user name, and 
create a new user name for you, with a new pass-
word.
Alternatively, another user having ‘security’ access 
level can log in and initialize the device. This will 
return all configuration information, including pass-
words, to the initial values.
In the case where no-one knows a password for a 
security level user, contact your supplier.
Using the Switch
You see network problems and the Packet LED 
is on continuously with constant collisions 
(viewed using the Port Traffic Statistics screen, 
refer to 
 on 
):
You are using PACE equipped devices and have the 
Interactive Access feature of PACE enabled at both 
ends of the link. Interactive Access must only be 
enabled at one end of the Switch-device link. Dis-
abling Interactive Access for a Switch port as 
described in 
You have configured a Switch port so that it 
‘blips’ when a broadcast storm occurs, but the 
port does not blip properly:
The broadcast storms are occurring such that the 
average broadcast bandwidth cannot drop below 
the Falling Threshold value. This means that the 
blip only occurs once.
Try changing the following attributes in the Broad-
cast Storm Control section of the Port Setup screen:
Rising Action to disable port/notify.
Falling Action to event + enable.
For more information, refer to 
 on