4.4  F-Timer Function 
 
 
 
 
                                     
             
 
An F-timer is integrated in the ERTEC 200 in addition to the system timers. This timer works independently of the system 
clock and can be used for fail-safe applications, for example. The F-timer is triggered via the alternative “F_CLK” function 
at the external “BYP_CLK” input. External triggering is not possible if the ARM946E-S is operated in a reserved test 
mode (Config[4:3] = 11).  
 
The following signal pins are available for the F-timer on the ERTEC 200. 
 
• 
External counter cable  
F_CLK 
 
Description of function: 
  
The asynchronous input signal of the external independent time base is applied at a synchronization stage via the 
BYP_CLK input pin (alternative F_CLK function). To rule out occurrences of metastable states at the counter input, the 
synchronization stage is implemented with three flip-flop stages. The count pulses are generated in a series-connected 
edge detection. All flip-flops run at the APB clock of 50 MHz.  
The F_COUNTER_VAL register is reset using an asynchronous block reset or by writing the value 0x XXXX 55AA (X 
means “don’t care) to the F-counter register “FCOUNT_RES”. The next count pulse sets the counter to 0xFFFF FFFF 
and the counter is decremented at each additional count pulse. The FCOUNT_RES register is cleared again at the next 
clock cycle. 
The count value can be read out by a 32-bit read access. While an 8-bit or 16-bit read access is possible, it is not useful 
because it can result in an inconsistency in the read count values. 
 
Note on input frequency: 
 
The maximum input frequency for the F-CLK is one-quarter of the APB clock. In the event of a quartz failure on the 
ERTEC 200, a minimum output frequency between 40 and 90 MHz is set at the PLL. This yields a minimum APB-CLK 
frequency of PLLOUT
min 
40 MHz
 
/ 6 = 6.6666 MHz. To rule out a malfunction in the edge evaluation, the F-CLK can not 
exceed APB-CLKmin  6.66 MHz/4 = 1.6666 MHz 
 
The figure below shows the function blocks of the F-counter.  
 
 
 
32-Bit Down-Counter
F-Counter-Val(31:0)
F-COUNTER-EN
 
BYP_CLK
 
Sync Stage: 
3 stages +  
edge detect+ 
enable
 
DIRECT_IN
 
Read: F-Counter-Val 
FCOUNT_RES
 
Reset
Write: F-Counter-Res 
 
Data = 0xXXXX 55AAh 
CLK APB
 
CLK_APB
 
EN
APB-Bus
F_CLK
 
CONFIG(4:3)
 
 
Figure 5: Block Diagram of F-Counter 
 
 
Copyright © Siemens AG 2007. All rights reserved.                  
43
             
ERTEC 200 Manual 