Siemens ERTEC200 Manual De Usuario

Descargar
Página de 97
 
UART_CLK 0x0070  4 
bytes R/W 
0x00000000
UART clock selection 
50MHz/6MHz 
Table 16: Overview of System Control Registers 
 
4.8.2 
System Control Register Description 
ID_REG 
   
 
R 
 
Addr.: 0x4000_2600 
     Default: 0x4027_0100
 
Description 
Identification of ERTEC 200.  
Bit No. 
Name 
Description 
31..16 
ERTEC200-ID 
ERTEC 200 identifier: 4027h  
15..8 
HW-RELEASE 
HW release: 01h 
7..0 
METALL-FIX 
Metal fix: 00h 
 
BOOT_REG     
 
R 
 
 
Addr.: 0x4000_2604       Default: Bootpins[3:0]
 
Description 
Boot mode pins BOOT[3:0] can be read  
Bit No. 
Name 
Description 
31..4 Reserved 
Reserved 
3 .. 0 
BOOT[3:0] 
Reading of Boot[3] pin 
 
CONFIG_REG   
 
R   Addr.: 
0x4000_2608 
    Default:Configpins[6:1]
 
Description 
ERTEC 200 config pins CONFIG[6:1] can be read. 
Bit No. 
Name 
Description 
31..7 Reserved 
Reserved 
6 .. 1 
CONFIG[6:1] 
Reading of CONFIG[6:1] pin 
0 Reserved 
Reserved 
 
RES_CTRL_REG 
 
W/R
   
 
Addr.: 0x4000_260C 
    Default: 0x0000_0004
 
Description 
Control register for reset of ERTEC 200 
Bit No. 
Name 
Description 
31..13 Reserved 
Reserved 
 
12:3 
PULSE_DUR 
Pulse duration of SW or watchdog reset. 
T
RES_PULSE
 = (8 x n + 8) x T
CLK
;  
T
CLK
:  
APB clock period (1/50 MHz = 20 ns) 
n:  
Value of PULSE_DUR (0 .. 1023) 
The integrated PHYs require a reset duration of > 100
µs. This requires the 
setting n > 625.
 
2 EN_WD_SOFT_ 
RES_IRTE 
0: The IRTE switch controller is not reset for the watchdog/soft reset. 
1: The IRTE switch controller is reset for the watchdog/soft reset.
 
XRES_SOFT 
1: Software reset (not latching) 
WD_RES_FREI 
1: Enable watchdog reset 
 
 
RES_ STAT _REG 
 
R   Addr.: 
0x4000_2610 
    Default: 0x0000_0004
 
Description 
Status register for reset of ERTEC 200. 
Only the bit of the last reset event occurrence is set. The two other bits are reset. 
Bit No. 
Name 
Description 
31..3 Reserved 
Reserved 
HW_RESET 
1: Last reset was PowerOn or Hardware reset 
SW_RESET 
1: Last reset was Software reset 
WD_RESET 
1: Last reset was Watchdog reset 
 
 
Copyright © Siemens AG 2007. All rights reserved.                  
59
             
ERTEC 200 Manual 
Technical data subject to change                                                                                                                                Version 1.1.0