Siemens ERTEC200 Manual De Usuario

Descargar
Página de 97
 
6.1  Address Assignment of EMIF Registers 
The EMIF registers are 32 bits in width. These registers can only be written to with double words. 
 
EMIF  
(Base Address 0x7000_0000) 
Register Name
 
Offset Address
 
Address Area
Access
 
Default
 
Description
 
Revision_Code_and 
_Status 
0x0000 
4 bytes 
0x00000100
Revision code and status register 
Async_Wait_Cycle 
_Config 
0x0004 
4 bytes 
W/R 
0x40000080
Async wait cycle config register 
SDRAM_Bank_ 
Config 
0x0008 
4 bytes 
W/R 
0x000020A0
SDRAM bank config register 
SDRAM_Refresh 
_Control 
0x000C 4 
bytes 
W/R 
0x00000190
Setting of refresh rate 
Indication for timeout 
Async_BANK0_ 
Config 
0x0010 4 
bytes 
W/R 
0x3FFFFFF2
Timing/data bus width for access 
via async. interface CS_PER0_N 
Async_BANK1_ 
Config 
0x0014 4 
bytes 
W/R 
0x3FFFFFF2
Timing/data bus width for access 
via async. interface CS_PER1_N 
Async_BANK2_ 
Config 
0x0018 4 
bytes 
W/R 
0x3FFFFFF2
Timing/data bus width for access 
via async. interface CS_PER2_N 
Async_BANK3_ 
Config 
0x001C 4 
bytes 
W/R 
0x3FFFFFF2
Timing/data bus width for access 
via async. interface CS_PER3_N 
Extended_Config 
0x0020 
4 bytes 
W/R 
0x03030000
Setting of additional functionalities
Table 19: Overview of EMIF Registers 
6.2  EMIF Register Description 
Revision Code and Status 
 
R     
Addr.: 0x7000_0000      Default: 0x0000_0100
 
Description 
Revision code and status register 
 
Bit No. 
Name 
Description 
31..16 Reserved 
Reserved 
15..8 MAJOR_REVISION 
01h 
7..0 MINOR_REVISION 
00h 
 
 
Async wait cycle config  
 
W/R    Addr.: 0x7000_0004      Default: 0x4000_0080
 
Description Async 
wait 
cycle config register 
 
Bit No. 
Name 
Description 
31 Reserved 
Reserved 
30 WP 
Wait 
polarity 
0: Wait if RDY_PER_N = 0 
1: Wait if RDY_PER_N = 1 
29..8 Reserved 
Reserved 
7..0 
MAX_EXT_WAIT 
This value multiplied by 16 is equivalent to the number of AHB clock cycles 
that the async. controller waits for RDY_PER_N before access is terminated 
with timeout IRQ. 
 
 
 
Copyright © Siemens AG 2007. All rights reserved.                  
70
             
ERTEC 200 Manual 
Technical data subject to change                                                                                                                                Version 1.1.0