Siemens ERTEC200 Manual De Usuario

Descargar
Página de 97
 
9 Multiport 
Ethernet 
PHY 
A 2-fold multiport PHY (Physical Layer Transceiver) that supports the following transfer modes is integrated in the 
ERTEC 200: 
• 10BASE-T 
• 100BASE-TX 
• 100BASE-FX 
 
These transfer modes are available separately for each port and can be set differently. 
 
The PHY is compatible with the following standards: 
• IEEE802.3 
• IEEE802.3u 
• ANSI 
X3.263-1995 
• ISO/IEC9314 
 
The data interface with the Ethernet MACs takes place via MII. The management interface can be addressed via the 
MDIO interface (SMI interface). The 25 MHz clock supply is to be provided as follows: 
• 
25 MHz quartz on the ERTEC 200 pins CLKP_A and CLKP_B or 
• 
25 MHz clock on the ERTEC 200 pin CLKP_A 
 
In addition to the basic functionalities of the transfer modes 10BASE-T, 100BASE-TX, and 100BASE-FX, the PHYs also 
support: 
• Auto-negotiation 
• Auto-crossing 
• Auto-polarity 
 
The following PHY registers can be assigned via the SMI interface:  
 
Register-Nr. 
Description 
Group 
0 Basic-Control-Register Basic 
1 Basic-Status-Register Basic 
2 PHY-Identifier 
Extended 
3 PHY-Identifier 
Extended 
Auto Negotiation Advertisement Register 
Extended 
Auto Negotiation Link Partner Ability Register 
Extended 
Auto Negotiation Expansion Register 
Extended 
Next Page Timing Register                   
Extended 
8 - 15 
Non-supported registers 
------ 
16 
Silicon Revision Code 
Vendor-specific 
17 ModeControl/ 
Status 
Register 
Vendor-specific 
18 Special 
Modes 
Vendor-specific 
19 
SMII Configuration Status Register 
Vendor-specific 
20 - 26 
Reserved 
Vendor-specific 
27 
Control/Status Indication Register 
Vendor-specific 
28 Special 
Internal 
Testability Register 
Vendor-specific 
29 
Interrupt Source Register 
Vendor-specific 
30 
Interrupt mask register 
Vendor-specific 
31 
PHY Special Control/Status Register 
Vendor-specific 
 
For an exact description of the PHY registers, refer to /13/. 
 
During a hardware reset or when leaving the Power Down State (Px_PHY_ENB = 1), an initial configuration is set on an 
internal Config port of the PHY. This configuration can be modified later in the PHY register set. The internal Config port 
comprises the following parameter assignment, which at present can be permanently set or set via software in the 
PHY_CONFIG system control register. 
 
 
Copyright © Siemens AG 2007. All rights reserved.                  
88
             
ERTEC 200 Manual 
Technical data subject to change                                                                                                                                Version 1.1.0