Siemens X-200 Manual De Usuario

Descargar
Página de 121
 
Diagnostics over Industrial Ethernet 
 
6.2 Web Based Management (WBM) 
 
Note 
Firewall 
When using a firewall, access to the following ports must be possible: 
- Telnet Port 23/TCP 
- http Port 80/TCP 
- SNMP Port 161/UDP 
- SNMP trap Port 162/UDP 
 
6.2.3 
Access over WBM 
How to Access Industrial Ethernet Switches of the SCALANCE X-200 Product Line over WBM 
1.  Open the Internet browser. 
2.  Enter the IP address or the URL of the Industrial Ethernet switch of the SCALANCE X-
200 product line in the address box of the Internet browser as follows:  
for example http://141.73.10.89 
and confirm with [RETURN]. 
3.  You can log on as administrator or as user. An administrator can read and modify 
parameters. A user has only read access. 
 
A dialog appears. You are prompted to enter your login and your password. 
– 
To log in as administrator: 
The login and the password are "admin" 
– 
To log in as user: 
The login and the password are "user" 
The administrator can change both passwords. 
 
 
Note 
After resetting to the factory defaults, the login and password are once again admin and 
user. 
 
 
 
Note 
Make sure that the passwords are kept in a safe place because they are required for access 
when configuring the devices! 
 
Industrial Ethernet SCALANCE X-100 and SCALANCE X-200 Product Line 
Commissioning Manual, 1,   
6-9