Connection 
 
5.2 Signaling contact 
 
SCALANCE X-200 
140
 
Operating Instructions, 12/2011, A5E00349864-19 
5.2 
Signaling contact 
Signaling contact 
The signaling contact (relay contact) is a floating switch with which error/fault states can be 
signaled by breaking the contact. 
The signaling contact is connected to a 2-pin plug-in terminal block.  
Exception: 
The signaling contact on the SCALANCE X204 IRT PRO and SCALANCE X202-2P IRT 
PRO is connected using a 5-pin b-coded M12 socket. 
 
IE Switches X-200 
SCALANCE X204 IRT PRO, 
SCALANCE X202-2P IRT PRO, 
SCALANCE X201-3P IRT PRO 
Pin number 
Assignment  Pin number 
Assignment 
 
 
 
 
Pin 1 
F1 
Pin 1 
F1 
Pin 2 
F2 
Pin 2 
n. c. 
Pin 3 
n. c. 
Pin 4 
F2 
Pin 5 
n. c. 
The following errors/faults can be signaled by the signaling contact: 
●  The loss and the establishment of a link on a monitored port. 
●  The failure of one of the two redundant power supplies. 
●  The loss of the connection to the controller in PROFINET IO mode. 
●  The redundancy manager signals an error 
Note 
 
 
SCALANCE X204 IRT PRO, SCALANCE X202-2P IRT PRO and SCALANCE X201-3P 
IRT PRO have no redundant power supply 
●  Incompatible C-PLUG was inserted. 
The connection or disconnection of a communication node on an unmonitored port does not 
lead to an error message.