Siemens SCALANCE X-200 Manual De Usuario

Descargar
Página de 296
Configuration / diagnostics using remote mechanisms 
 
6.3 Configuration using Web Based Management (WBM) and Command Line Interface (CLI) 
 
SCALANCE X-200 
156
 
Operating Instructions, 12/2011, A5E00349864-19 
6.3 
Configuration using Web Based Management (WBM) and 
Command Line Interface (CLI) 
Introduction 
To make the best possible use of the technical possibilities of the IE switches, you can adapt 
the configuration of the device to the concrete situation in which it is used. There are two 
ways of configuring an IE switch: 
●  With the Command Line Interface, you can configure IE switches via Telnet or SSH (an 
Ethernet connection is necessary). You can enable or disable Telnet or SSH using Web 
Based Management. 
●  Web Based Management accesses the configuration of an IE switch over a Web 
browser. An Ethernet connection to the IE switch is necessary. 
NOTICE 
 
 
Depending on the selected configuration method, the following mechanisms are 
integrated to prevent unauthorized access to an IE switch: 
 
CLI via TELNET or SSH 
A CLI session is interrupted automatically if no input is made for more than five 
minutes. This value can be assigned using the CLI (up to 600 s). The automatic 
interruption of a CLI session can also be disabled with CLI. 
 
Web Based Management 
There is an automatic logout after 5 minutes; you can, however, also log out 
manually using a "Logout" button on the user interface located in the header of Web 
Based Management. Exiting the browser does does not close the session. If the 
browser is started again within these 5 minutes, the session continues to be used. 
 
 
Note 
All the configuration changes are adopted in the flash memory after approximately 1 minute 
or after a warm restart. You should therefore run the "Restart" command in the command 
line interface or in Web Based Management before turning off the device. You can then be 
certain that all the configuration changes have been saved. 
 
 
Note 
To use SNMP Management, RMON, and traps, you require a network management station. 