Magnum 4K16 Switches    Installation and User Guide       
(12/05) 
 
14 
www  GarrettCom  com
.
.
 
3.0  
Installation 
Before installing the equipment, it is necessary to take the 
following precautions: 
1.) 
If the equipment is mounted in an enclosed or multiple rack 
assembly, the environmental temperature around the equipment 
must be less than or equal to 50
0
C. 
2.) 
If the equipment is mounted in an enclosed or multiple rack 
assembly, adequate air flow must be maintained for proper and 
safe operation. 
3.) 
If the equipment is mounted in an enclosed or multiple rack 
system placement of the equipment must not overload or load 
unevenly the rack system. 
4.) 
If the equipment is mounted in an enclosed or multiple rack 
assembly, verify the equipment’s power requirements to prevent 
overloading of the building/s electrical circuits. 
5.)  
If the equipment is mounted in an enclosed or multiple rack 
assembly verify that the equipment has a reliable and 
uncompromised earthing path.
 
6.)  
If the intra-building wiring (cabling) is involved with this 
product(NEBS), then it is recommended to have shielded cable and 
the shield is grounded at both ends.
 
 
 
Installation:  This section describes installation of the Magnum 4K-Series Switches, as 
well as connection of the various Ethernet media types. 
3.1 
Locating Magnum 4K16 Switches 
 
The location of a Magnum 4K-Series Switch is dependent on the physical 
layout of the network.  Typically the Switch is placed in a central wiring location where 
groups of network devices need to be connected in order to communicate with each 
other. These Switches are typically rack mounted in a wiring closet see Section 3.3.2 
below), but because they have rubber feet they can also be installed on a shelf or table 
top.  
Locate an AC receptacle that is within six feet (2 meters) of the intended Magnum 4K-
Series site.  The rugged metal case of the Magnum 4K-Series will normally protect it 
from accidental damage in a lab or workplace setting.  Maintain an open view of the 
front to visually monitor the status LEDs.  Keep an open area around the unit so that 
cooling can occur from the small fan on the top of the silicon, while the unit is in 
operation. See figure below. 
Figure 3.1:  Location of 
16-port Magnum 
4K16’s cooling fan air 
exhaust 
 
 
 
 
 
F
H
ON
OFF
110-220
VAC
47-63Hz
1.0-0.5A