Express Ethernet Switch LB9217A-R2 & Applicable Modules 
13 
 
Connecting to Your Network 
Cabling 
 
y First, ensure the power of the switch and end devices is turned off. 
 
<NOTE>  Always ensure that the power is off before any installation.  
 
y Prepare cable with corresponding connectors for each type of port in use.  
 
<NOTE>  To connect two regular RJ-45 ports between switches or hubs, 
you need a cross-over cable. 
 
y Consult Table 3 below for cabling requirements based on connectors and speed. 
 
y Connect one end of the cable to the switch and the other end to a desired device.  
 
y Once the connections between two end devices are made successfully, turn on the 
power and the switch is operational. 
 
Cable Length 
 
The maximum distance between a node and a directly connected switch port on a 
100BaseFX network is 120 km using 10/125µm single-mode fiber optic cable. It is 
capable of spanning at most 2 kilometers when use of 62.5/125µm multi-mode fiber-
optic cable. 
 
Table 3: Cable Specifications 
Speed Connector 
Port 
Speed
Half/Full 
Duplex 
Cable Max. 
Distance 
10BaseT 
RJ-45 
10/20 Mbps  Cat. 3, 4 or 
5 UTP/STP 
100 m 
100BaseTX RJ-45 
100/200 
Mbps 
Cat. 5 
UTP/STP 
100 m 
100BaseFX 
ST, SC, MT-
RJ, VF-45, 
LC 
100/200 
Mbps 
62.5/125 
µ
m multi-
mode fiber 
2 km 
 
100BaseFX SC, 
ST 
100/200 
Mbps 
10/125  µm 
single-mode 
fiber 
120 km