Gateway 6400 Manual De Usuario

Descargar
Página de 148
124
Reference Data
Environmental specifications
The following specifications identify maximum environmental conditions. At 
no time should the server run under conditions which violate these 
specifications.
Network Interface
Integrated Intel 82559 PCI ethernet controller.
Video
Integrated ATI Rage-XL PCI-based VGA controller with 4 MB of PC100
SDRAM.
Expansion Slots
Seven PCI slots (two 64-bit/33 MHz and five 32-bit/33 MHz).
Power Supply
300 watts. ATX power connector for easy power cable changeover.
Certification
FCC Class A, UL, CUL, CE Mark, VCCI, CB Scheme.
Variable
Requirements
Temperature
Maximum rate of change = 10° C per hour
Nonoperating
–48.3° to 65.5° C (–55° to 150° F)
Operating
5° to 35° C (41° to 95° F); derated 0.5° C for every
1000 ft. (305 m)
Altitude
10,000 ft. max
Humidity
Nonoperating
95% relative (noncondensing) at 30° C (86° F)
Operating wet bulb Not to exceed 33° C (91.4° F) (with diskette drive or hard
disk drive)
Shock
Operating
2.0 g, 11 msec, 1/2 sine
Packaged
Operational after 30-inch free fall (cosmetic damage
might occur)
AC Input Power
100-120 V
100-120 V
, 6 A, 50/60 Hz
200-240 V
200-240 V
, 3 A, 50/60 Hz
05032.book Page 124 Monday, July 10, 2000 11:43 AM