Brocade Communications Systems DCX 8510-4 Manual De Usuario

Descargar
Página de 168
28
Brocade DCX 8510-4 Backbone Hardware Reference Manual
53-1002177-05
Customizing a switch name
3
NOTE
Connecting the CP blades to a private network/VLAN is recommended.
By establishing an Ethernet connection, you can complete the Brocade DCX 8510-4 configuration 
using either a serial session, Telnet, or management applications, such as Web Tools or Brocade 
Network Advisor.
Perform the following steps to establish an Ethernet connection to the Brocade DCX 8510-4.
1. Remove the shipping plug from the Ethernet port on the active CP blade.
2. Insert one end of an Ethernet cable into the Ethernet port.
3. Connect the other end to an Ethernet 10/100/1000 BaseT LAN.
The Brocade DCX 8510-4 can be accessed through a remote connection using the command 
line via Telnet or any of the management tools, such as Web Tools or Brocade Network Advisor.
4. To complete any additional Brocade DCX 8510-4 configuration procedures through a Telnet 
session, log in to the Brocade DCX 8510-4 by Telnet, using the admin login. The default 
password is password.
Customizing a switch name
The switch name of the Brocade DCX 8510-4 can be up to 30 characters long using Fabric OS 
release 6.3.0 or later; can include letters, numbers, hyphens, and underscore characters; and 
must begin with a letter. 
NOTE
Changing the name causes a domain address format RSCN to be issued.
1. Type switchName followed by the new name in double quotes.
swDir:admin> switchName "swModularSwitch5"
Committing configuration...
Done.
swModularSwitch5:admin>
2. Record the new name for reference.
Customizing a chassis name
The chassis name of the Brocade DCX 8510-4 can be up to 15 characters long; can include letters, 
numbers, hyphens, and underscore characters; and must begin with a letter. 
1. Enter chassisName followed by the new name in double quotes.
switch:admin> chassisname "DCX8510_chassis"
Committing configuration...
Done.