Color Change
312776F
67
Color Change
Color Change Procedures
Multiple Color Systems
1. Shut off air to the gun.
2. Place the gun in the gun flush box if used, and close 
the lid.
3. Switch to Standby
 
 mode at the Booth Control.
4. Use the scroll keys, 
 
or
 
to select the new 
color. Press Enter 
 
to begin the color change 
sequence.
5. If a gun flush box is not used, trigger 
the gun into a grounded metal pail 
until the color change sequence is 
complete. 
6. When the color change indicator light stops flashing 
on the Booth Control, the color change sequence is 
complete.
NOTE: The color change timer does not start until 
the gun is triggered and fluid flow is detected. If no 
flow is detected within 2 minutes, the color change 
operation aborts. The Booth Control enters Standby 
 mode at the previous color.
7. When you are ready to spray, remove the gun from 
the gun flush box if used, and close its door. 
NOTE: The gun flush box door must be closed for 
the atomizing air valve to open.
8. Press the Mix 
 key to start spraying.
Single Color Systems
1. Follow procedure for Purging Fluid Supply Sys-
2. Load the new color. SeStart Up, page 53.
3. Press the Mix 
 key to start spraying.
Color Change Sequences
. 71 through F
. 80 illustrate various color change 
sequences. See Table 9 to determine which figure to 
reference, based on the recipe change and system con-
figuration. The time sequences are detailed in the fol-
lowing paragraphs.
NOTE: For software version 2.04.xxx and older, the sys-
tem uses the color/catalyst purge and fill times from the 
new recipe.
NOTE: See Setup Mode on page 25 to select purge 
sources and set desired purge, chop, and fill times.
NOTES:
The system uses old recipe data for the purge cycle. 
However, it opens the new color/catalyst valve 
based on the new recipe data. 
The system uses the new recipe data for the fill 
cycle.
For the one gun flush box (GFB) option, the spray 
gun must be inserted in the GFB during the entire 
color change cycle (purge and fill). The GFB trigger 
output will be on during the recipe change cycle.
For the two gun flush box (GFB) option, both spray 
guns must be inserted in the GFBs during the entire 
color change cycle (purge and fill). The system will 
turn each GFB trigger output on and off based on 
the preset time for each gun.
For Special Outputs options, the system will turn 
each output on and off based on the preset times. 
Each Special Output has two different start times 
and durations.
For systems without dump valves, the First Purge 
begins after the Color/Catalyst Change steps are 
completed.
Dump Valve B is required for a Catalyst Change 
system.
When going from Recipe X to Recipe 0, only the 
purge cycle data from Recipe 0 is used.
When going from Recipe 0 to Recipe Y, only the fill 
cycle data from Recipe Y is used.