Perlick DC72S Manual De Usuario
Connecting the Regulator to the
CO
CO
2
Cylinder
■
Remove blue plug from regulator fitting.
(Note: Do not remove the carbonic washer).
■
Screw regulator onto gas cylinder valve.
Tighten with wrench until vertically straight.
Be sure that shut-off valve (
black lever) on
regulator is in the OFF (
horizontal) position.
■
Place a screw clamp over end of red air line
and push onto regulator tailpiece. Tighten
clamp with a screwdriver.
Adjusting the CO
2
Gas Flow
■
Turn regulator adjusting screw counterclock-
wise until it turns freely.
■
Turn hand valve counterclockwise on CO
2
cylinder to the fully open position.
■
Turn regulator adjusting screw clockwise until
desired pressure is reached (approximately
12-15 lbs.). Tighten stop nut on adjusting screw.
■
Open shut-off valve on bottom of regulator.
CO
2
Leak Test
Dilute a small amount of liquid dishwashing soap
and rub the soapy mixture around each connec-
tion. If bubbles appear, tighten connection.
Replacing CO
2
Gas Cylinder
■
Turn CO
2
hand valve clockwise until seated and
close shut-off valve on regulator.
■
unscrew regulator from cylinder fitting.
■
Replace carbonic washer (Part No. 157F2P),
if needed and reattach regulator to filled
cylinder.
■
Turn CO
2
hand valve counterclockwise until
fully open. Turn regulator shut-off valve to
open position.
■
Adjust CO
2
gas flow as required, turning
clock wise for higher pressure.
Proper CO
2
Handling
always
...
■
Connect a regulator (reducing valve) to
CO
2
cylinder.
■
Secure cylinder in upright position whether in
storage or in use.
■
Keep cylinder away from heat. Rupture disc
vents at 122° F. maximum.
■
Ventilate room after high pressure gas leakage.
■
Check the last DOT test date on cylinder neck
before filling. If more than five years old, the
cylinder must be retested to DOT specifications.
■
Be sure CO
2
cylinder outlet fitting is free of dust
or dirt before attaching regulator.
■
Store CO
2
cylinder and regulator assembly
upright.
■
Allow only properly trained and experienced
personnel to handle high pressure gas.
never
...
■
Connect cylinder directly to a keg without a
regulator (reducing valve).
■
Drop or throw regulator or CO
2
cylinder.
■
Transport CO
2
cylinder in a closed vehicle.
■
Apply oil to a regulator.
■
Shut off CO
2
cylinder when not in use. You will
not save gas by doing so!
■
Allow untrained, inexperienced personnel to
handle high pressure gas.
Failure to heed this warning could result in
personal injury or death.
Form No. Z2283
Rev. 06.14.10
5
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Installation and Tapping –
Concessionaire Dispensers
CO2
PRESSURE
GAUGE
CO2
GAS
DRUM
REGULATOR
FITTING
REGULATOR
ADJUSTING
SCREW
FITTING FOR
RED AIR HOSE
SHUT-OFF VALVE
(BLACK LEVER IN
CLOSED POSITION)
HAND
VALVE
PERLICK
PSI
10
50
0
60
20
40
30