Cisco Systems 3750E Manual De Usuario

Descargar
Página de 1236
 
45-9
Catalyst 3750-E and 3560-E Switch Software Configuration Guide
OL-9775-02
Chapter 45      Troubleshooting
Recovering from a Command Switch Failure
the switch current-stack-member-number renumber new-stack-member-number global 
configuration command to manually assign a stack member number. For more information about 
stack member numbers, see the 
If you replace a stack member with an identical model, the new switch functions with the exact same 
configuration as the replaced switch. This is also assuming the new switch is using the same member 
number as the replaced switch.
Removing powered-on stack members causes the switch stack to divide (partition) into two or more 
switch stacks, each with the same configuration. If you want the switch stacks to remain separate, change 
the IP address or addresses of the newly created switch stacks. To recover from a partitioned switch 
stack:
1.
Power off the newly created switch stacks. 
2.
Reconnect them to the original switch stack through their StackWise Plus ports. 
3.
Power on the switches.
For the commands that you can use to monitor the switch stack and its members, see th
Recovering from a Command Switch Failure
This section describes how to recover from a failed command switch. You can configure a redundant 
command switch group by using the Hot Standby Router Protocol (HSRP). For more information, see 
For more information, see 
 and 
 Also see the Getting Started with 
Cisco Network Assistant, available on Cisco.com. 
Note
HSRP is the preferred method for supplying redundancy to a cluster.
If you have not configured a standby command switch, and your command switch loses power or fails 
in some other way, management contact with the member switches is lost, and you must install a new 
command switch. However, connectivity between switches that are still connected is not affected, and 
the member switches forward packets as usual. You can manage the members as standalone switches 
through the console port, through the Ethernet management port, or, if they have IP addresses, through 
the other management interfaces.
You can prepare for a command switch failure by assigning an IP address to a member switch or another 
switch that is command-capable, making a note of the command-switch password, and cabling your 
cluster to provide redundant connectivity between the member switches and the replacement command 
switch. These sections describe two solutions for replacing a failed command switch:
These recovery procedures require that you have physical access to the switch.
For information on command-capable switches, see the release notes.