Cisco Systems 3750E Manual De Usuario

Descargar
Página de 1236
 
45-26
Catalyst 3750-E and 3560-E Switch Software Configuration Guide
OL-9775-02
Chapter 45      Troubleshooting
Using On-Board Failure Logging
file is created, you can use the rename privileged EXEC command to rename it, but the contents of the 
renamed file will not be displayed by the show stacks or the show tech-support privileged EXEC 
command. You can delete crashinfo files by using the delete privileged EXEC command. 
You can display the most recent basic crashinfo file (that is, the file with the highest sequence number 
at the end of its filename) by entering the show stacks or the show tech-support privileged EXEC 
command. You also can access the file by using any command that can copy or display files, such as the 
more or the copy privileged EXEC command. 
Extended crashinfo Files
The switch creates the extended crashinfo file when the system is failing. The information in the 
extended file includes additional information that can help determine the cause of the switch failure. You 
provide this information to the Cisco technical support representative by manually accessing the file and 
using the more or the copy privileged EXEC command. 
Extended crashinfo files are kept in this directory on the flash file system:
flash:/crashinfo_ext/.
The filenames are crashinfo_ext_n where n is a sequence number. 
You can configure the switch to not create the extended creashinfo file by using the no exception 
crashinfo
 global configuration command.
Using On-Board Failure Logging
You can use the on-board-failure logging (OBFL) feature to collect information about the switch and the 
field-replaceable unit (FRU) devices that are connected to it. The information includes uptime, 
temperature, and voltage information and helps Cisco technical support representatives to troubleshoot 
switch problems. We recommend that you keep OBFL enabled and do not erase the data stored in the 
flash memory.
This section has this information:
Understanding OBFL
By default, OBFL is enabled. It collects information about the switch and the FRU devices, including 
power supplies, redundant power systems, and small form-factor pluggable (SFP) modules. The switch 
stores this information in the flash memory:
CLI commands—Record of the OBFL CLI commands that are entered on a standalone switch or a 
switch stack member
Environment data—Unique device identifier (UDI) information for a standalone switch or a stack 
member and for all the connected FRU devices: the product identification (PID), the version 
identification (VID), and the serial number
Message—Record of the hardware-related system messages generated by a standalone switch or a 
stack member