Section 4 – Connections
06/97 – 1.00 – 4-1
4 – Connections
This section explains how to connect other equip-
ment to the DA-98 in a variety of situations. It is 
not intended as a complete reference to the use of 
the DA-98. See the appropriate sections for full 
details of how these connectors are used. 
4.1 Audio connections
Other audio equipment can be connected to the 
DA-98 either using analog or digital interfaces.
4.1.1 Analog audio connections
All analog audio connections to the DA-98 are 
made through 25-pin D-sub connectors (input sig-
nals through [47] and output signals through [48]).
This allows convenient and tidy cabling between 
the DA-98 and other units such as the TASCAM 
M-1600 series of mixing consoles.
It is not recommended that you make up your own 
cables–consult your TASCAM dealer for avail-
ability of suitable ready-made cables (and see 
15.1.5, “Cables”). However,we recognize that 
every situation has its own unique features, and 
there are occasions when a special cable must be 
made. 
Before starting to make the cable, we suggest you 
contact your TASCAM dealer for full details of 
cable specifications, etc.
The pinouts for both the 
ANALOG OUTPUT
 and 
INPUT
 connectors are as follows:
where 
G
=ground, 
H
=”hot” (+) and 
C
=”cold” (–).
All audio inputs are balanced and are rated at a 
nominal +4dBu level.
The impedance of the inputs is 20k
Ω
 and that of 
the outputs is 10
Ω
.
4.1.2 Digital audio connections
Digital audio input and output signals are carried 
on the same 25-pin D-sub connector [45]. The sig-
nals are in TDIF-1 format.
To carry signals between a DA-98 and another 
DTRS unit, use a PW-88D cable (1 meter long) or 
a PW-88DL cable (5 meters long). You may also 
use these cables to connect the DA-98 to other 
TDIF-1-equipped devices.
If you need to connect the DA-98 to a digital 
audio source using a different format, we recom-
mend the use of the following units:
TASCAM IF-88AE Interface Unit – converts 
between the TDIF-1 and AES/EBU formats (8 
channels). It also provides S-PDIF format con-
version facilities.
TASCAM IF-88SD Interface Unit – converts 
between the TDIF-1 and SDIF-2 digital audio 
formats.
4.2 Synchronization 
connections
The DA-98 is equipped with sophisticated facili-
ties for control and synchronization with other 
units. For full details of how to operate the DA-98 
with other units, see 10, “Operations related to 
timecode”
.
4.2.1 Analog timecode connections
The DA-98 can be synchronized to externally-
generated timecode and is also equipped with an 
internal timecode generator. For full details of 
WARNINGS
When making connections between the DA-98 and 
other equipment, whether audio or control, both the DA-
98 and the other equipment must be turned off, other-
wise damage may be caused to the DA-98 and/or the 
other equipment.
Only use TASCAM-supplied and TASCAM-approved 
cables when making connections to the DA-98. Though 
the cables and connectors may resemble computer 
cables, they serve different purposes, and meet a differ-
ent set of specifications. The use of cables other than 
TASCAM cables will at best cause the equipment to 
work erratically, and at worst cause damage to the 
equipment.
If the use of cables other than TASCAM cables causes 
or results in damage, the warranty is voided.