Section 10 – Operations related to timecode
06/97 – 1.00 – 10-13
the slave is now 10 minutes and 4 frames behind 
the master.
Since the slave is meant to be exactly 10 minutes 
behind the master, the difference, +4 frames, is the 
“relative difference” between the master and the 
slave.
To view the absolute and relative differences 
between master and slave machines:
1) Go to group menu E:
2) Move the cursor to either 
Abs Diff
 
(absolute difference) or 
Rel Diff
 (relative 
difference). The appropriate value will be 
shown on the bottom line of the display screen.
10.7.9 Rechasing timecode
When timecode is received, the DA-98 can either 
constantly monitor the internal off-tape timecode 
(or the ABS equivalent as set in 10.2, “Tape time-
code mode”)
 and the external timecode, issuing 
“speed-up” and “slow-down” messages to the 
transport to keep itself in sync (rechasing), or it 
can synchronize once and run freely, ignoring the 
incoming timecode.
While the DA-98 is re-syncing (speeding up and 
slowing down), playback output will be muted, 
unless the clock is set to 
INT
). Usually you should 
find that the DA-98 does not need to rechase, 
however, and you can leave it in free-running 
mode. If the timecode master tape includes a 
break in the timecode, though, you may want the 
DA-98 to rechase the master.
As well as selecting rechase, you can also select 
the length of the “rechase window”. This means 
that if the difference between internal and incom-
ing timecode is greater than the value of this win-
dow (1 or 2 seconds in the case of the DA-98), the 
synchronizer will start to rechase.
1) Go to menu group 4, move the cursor to 
Rechs Mod
 (rechase mode) and press 
ENTER
:
2) Use the 
LEFT
 and 
RIGHT
 keys to select the 
Mode
 field, and the 
UP
 and 
DOWN
 keys to 
choose between 
rechase
 and 
free
3) If you select 
rechase
, use the 
RIGHT
 key to 
move to the 
Window
 field, and select a window 
of either 
1
 or 
2
 seconds.
10.7.10Bypassing timecode errors
As timecode is received from a remote master 
unit, it may be subject to errors (dropouts on the 
timecode master tape, etc.). These errors can 
cause synchronization failure (the DA-98 will no 
longer be locked to the timecode of the master 
unit).
You can set the DA-98 to bypass and ignore 
incoming timecode errors of up to 30 frames in 
length, or up to 10 frames in length.
1) Go to menu group 4, move the cursor to 
ErrBypass
 (Error Bypass), and press 
ENTER
:
2) Use the 
UP
 and 
DOWN
 keys to select between 
10
 and 
30
 
Frame
.
E x t
T C
A b s
D i f f
T a p e
T C
R e l
D i f f
G e n
T C
0 0 : 0 0 : 0 0 : 0 4
2 5 F
Slave (offset set to
+00:10:00:00
)
Master
Tape counter
shows:
10:05:12:08
but should be
10:05:12:12
Tape counter
shows:
10:15:12:12
Absolute difference =
+00:10:00:04
Relative difference =
+00:00:00:04
R e c h a s e
M o d e
M o d e
W i n d o w
r e c h a s e
1
s e c
E r r o r
B y p a s s
1 0
F r a m e