CMA Dishmachines CMA-180UC Manual De Usuario

Descargar
Página de 25
Getting Started   
2.2.4.  NOVA Detergent and Rinse Dispenser (Optional)
The NOVA Detergent and Rinse Dispenser has its own reference manual.  
Familiarize yourself with the dispenser’s reference manual before proceeding with 
installation. 
1.  The NOVA dispenser is pre-wired with a multi-conductor electrical cable that is to 
be run through a conduit to the power block inside the control panel drawer.  Use 
a ½” watertight conduit meeting all local and national codes.  A conduit fitting is 
present on the bottom of the dispenser where the power cable exits.  A mounting 
plate to receive the ½” conduit is provided on the top right-hand corner (facing 
the back) of the machine.   
i. 
Run an appropriate length of ½” conduit from your dispenser to the mounting 
plate where it will be secured.  The conduit needs to be of sufficient length 
and flexibility to permit the machine to be moved for cleaning without having 
to disconnect any wiring. 
ii.  Run your dispenser wires through the conduit and through the enclosed area 
across the top of the machine and then feed them through the access hole 
provided in the back of the control panel drawer. 
iii.  With the machine’s power “OFF”, connect your detergent and rinse dispenser 
wires to the power block supplied and labeled (“DISPENSER 110V - 3 AMPS 
MAX”) inside the control panel drawer.  The table that follows lists the 
function of each conductor of the multi-conductor electrical cable. 
 
Wire Colors 
Circuit Voltage 
Function 
Gray/Violet 
90 VAC-130 VAC 50/60 Hz 
Main AC Power 
Black 
90 VAC-130 VAC 50/60 Hz 
Main AC Power 
Brown 
No Connection. Insulate this wire! 
This wire is LIVE! 
Yellow 
90 VAC-130 VAC 50/60 Hz 
Detergent Signal 
White/Yellow 
90 VAC-130 VAC 50/60 Hz 
Detergent Signal 
Violet 
90 VAC -130 VAC 50/60 Hz 
Rinse Signal 
White/Violet 
90 VAC -130 VAC 50/60 Hz 
Rinse Signal 
 
The individual conductors need to be connected as shown in Figure 2.2.4 
and as described on next page. 
 
                                                      
1
 All electrical and plumbing connections must be made by a qualified person who will comply with 
all available Federal, State, and Local Health, Electrical, Plumbing and Safety codes  
 
MODEL CMA-180UC INSTALLATION & OPERATION MANUAL Rev. 1.13 
Page 
7