Bunn FPG-2 Manual De Usuario

Descargar
Página de 79
30
P1745
FIG. 20 CAPACITOR
Location:
  The capacitor is located inside the front panel of 
the hopper housing next to the Off/On/Start switch.
Test Procedure:
1.  Disconnect grinder from the power source.
2.  Visually inspect the capacitor for leakage. If leakage 
is visible, replace the capacitor.
3.  Connect the grinder to the power source, if the mo-
tor does not run, disconnect the capacitor wiring 
harness from the main wiring harness. If the motor 
now runs, replace the capacitor.
Capacitor (Model LPG only)
P1747
FIG. 21 CAPACITOR TERMINALS
OF
F/S
TO
P
ST
AR
T
1. 
Pla
ce 
filte
r in
to f
unn
el a
nd 
slid
e fu
nne
l in
to r
ails.
2. 
Mo
me
nta
rily
 pu
sh 
the
 sw
itch
 to 
"ST
AR
T" 
pos
itio
n.
3. 
Gri
nde
r w
ill a
uto
ma
tica
lly 
sto
p w
hen
 fin
ish
ed.
+
BLK
WHI/BRN
Removal and Replacement:
1.  Disconnect the capacitor wiring harness from the 
main wiring harness.
2.  Remove the #8-32 nut attaching the capacitor and 
mounting bracket to the hopper housing and remove 
the bracket, shield, capacitor and capacitor wiring 
harness as an assembly.
3.  Disconnect the wiring harness from the capacitor 
and attach it to a new capacitor making sure the 
black wire attaches to the positive (+) pole, FIG. 
21.
4.  Wrap the shield around the capacitor and place into 
the mounting bracket. Slide the lower tab of the 
mounting bracket between the wrapper and base 
and secure in place over the mounting stud with 
the #8-32 nut.
5.   Reconnect the wiring harness to the main wiring 
harness.
SERVICE (Cont.)
41545 122209