Smeg CB66CES1 Manual De Usuario

Descargar
Página de 13
 
 
Instructions for the installer 
 
 
7
 
 
2.2  Electrical connection 
 
   
  Check that the voltage and size of the power supply line are as specified on the nameplate inside the 
storage compartment. 
This nameplate must never be removed. 
 
 
   
  If a permanent connection to the electrical mains is used, the appliance's power supply line must be 
fitted with an omnipolar breaking device with contact breaking gap of at least 3 mm located in an 
easily accessible position close to the appliance itself. 
 
 
   
  Complete wiring up to power supply with an appropriately rated five-core plug (see data plate) or, in 
case of operation from a 230-240V
∼ power supply, with a three-core plug. Make sure that plug and 
wall socket are of the same type and are in conformity with regulations in force. Make sure that the 
appliance is properly earthed. Before powering, check that the power line is properly earthed. Avoid 
using adapters or shunters. 
 
 
   
For operation on 400/415V3N
: use an H05RR-F / H05RN-F / 
 
H05V2V2-F type five-core cable (5 x 2.5 mm
2
). 
 
   
 
 
 
 
For operation on 400/415V2N
: use an H05RR-F  / H05RN-F / 
H05V2V2-F type five-core cable (cavo di 4 x 2.5 mm
2
). 
 
 
 
 
 
For operation on 230/240V
: use an H05RR-F  / H05RN-F / 
H05V2V2-F (cavo di   3 x 4 mm
2
). 
 
The cable end to be connected to the appliance must be provided with 
 
an ground wire (yellow-green) at least 20 mm longer. 
 
   
 
The manufacturer declines all responsibility for damage to persons or things caused by 