Smeg PGF75-3 Manual De Usuario

Descargar
Página de 16
 
Instructions for the installer
 
 
 
 
 
  3.2
  Burner and nozzle characteristics table 
 
Burner 
Rated 
heating 
capacity 
(kW) 
 
LPG – G30/G31  30/37 mbar 
 
 
Nozzle 
diameter 
1/100 mm 
By-pass 
mm 
1/100 
Reduced 
flow rate 
(W) 
Flow rate 
g/h G30 
Flow rate 
g/h G31 
Auxiliary (1) 
1.05 
50 
30 * 
27/28 ** 
400 
76 
75 
Semi rapid (2) 
1.75 
65 
33 * 
32/33 ** 
500 
127 
125 
Ultra Rapid (3) 
4.0 
100 
63 *
63/65 ** 
1600 
291 
286 
*/**: diameters marked * and ** must be fitted respectively on valves marked * and 
**shown in point "4.1 Adjusting the minimum setting for natural gas".
 
 
 
Burner 
Rated 
heating 
capacity 
(kW) 
 
Natural gas – G20  20 mbar 
 
 
Nozzle diameter 
1/100 mm 
Reduced flow rate 
(W) 
Auxiliary (1) 
1.05 
72 
400 
Semi rapid (2) 
1.75 
97 
500 
Ultra Rapid (3) 
4.0 
135 
1600 
 
 
 
  3.3
  Arrangement of burners on cooking hob 
 
 
 
 
 
 
BURNERS 
 
1.
  Auxiliary   
2.
  Semi rapid  
3.
  Ultra rapid 
29