Problem 
Possible Causes 
Action Required 
Mixer will not run.  
Bowl guard not closed. 
Rotate guard to the right until fully closed.  
 
Bowl not raised. 
Raise bowl to highest position.
 
 
Timer is not engaged. 
Turn timer at least fi ve minutes past “0”, then to  
 
 
 
desired time or set time to the green “on” position.
 
Power not connected properly. 
Check all power connections. Plug into a live socket.  
 
 
(Do not use extension cord!)  Test socket with  
 
  
another 
item.
 
 
Building circuit breaker is off. 
Check breaker box.  
 
Internal overload tripped.  
SP25 & smaller models: Press stop button then  
 
 
 
press reset button.  Larger models: Wait two  
 
 
 
minutes. Press stop button then press start button.   
 
 
(If overload continues to trip, reduce batch size 
 
 
and/or adjust recipe!) 
 
Gear not engaged. 
Switch gear fully into position. (Mixer will not operate  
 
 
if the speed control lever is positioned in between    
  
speeds)
Mixer stops during 
Internal overload tripped.  
SP25 & smaller models: Press stop button then 
mixing. 
 
press reset button.  Larger models: Wait two  
 
 
 
minutes. Press stop button then press start button.   
 
 
(If overload continues to trip, reduce batch size 
 
 
and/or adjust recipe!) 
 
Damaged or broken transmission belt.  SP25 & larger models: Technician to replace belt. 
 
Speeds were changed during mixing,   Return speed control lever to a speed model  
 
 
SP80PL only. 
position and restart the mixer.
Mixer is noisy. 
Mixer is not installed on level surface.  Adjust surface or relocate mixer.  Make sure rubber  
 
 
feet are installed. 
 
Bowl not seated correctly or clamps  
Ensure bowl is seated into bowl cradle correctly and  
 
not in place. 
bowl clamps are locked into place.
  
 Agitator 
not 
fi tted properly. 
Remove and attach agitator into position properly.  
 
Overloading bowl. 
Reduce batch size. (See Capacity Chart
 
Damaged or worn belt. 
Replace belt. 
 
Planetary ring gear needs  
Technician to inspect for source of noise.     
 
 
more grease. 
Reapply high-pressure grease.
 
 
Safety guard seized   Clean & lubricate slide sheath. 
Technician must drop down planetary to access mat 
(will not move freely).   
& sheath. 
Agitators won’t go 
Lack of lubrication and/or cleaning 
Wipe planetary shaft with a clean damp cloth and
onto the planetary 
of the planetary shaft. 
lubricate the shaft with mineral oil or food quality
shaft easily. 
 
grease.