Bakers Pride ALF-FC Manual De Usuario

Descargar
Página de 60
Automatic Lift Fryer 
 
Maintenance 
 
 
27 
10.  Before draining the cleaning solutionremove the filter bag, screen and pipe connections from 
the filter vat. This must be done before draining the cleaning solution. NEVER pump water or 
detergent through the filter system. 
 
11.  After 15 minutes, slowly open the drain valve. Drain the solution into the filter vat and discard. 
 
12.  Rinse the pot with hot water, using the pot brush to remove remaining sediment, drain and 
discard. 
 
13.  Close the drain and refill the fryer pot with hot water to the proper level. 
 
14.  Add approximately 4 to 6 ounces of distilled (white) vinegar to develop a neutralizing solution. Stir 
the solution briefly. Leave in the pot for three to five minutes and discard. NOTE: Foaming of 
shortening after boil-outs is caused by failure to follow proper neutralizing procedures.
 
 
15.  Repeat steps 12 through 14 as needed to remove all traces of cleaning solution. 
 
16.  Rinse the pot again with Cool water, drain and discard. 
 
 
Damage to the fryer could result if the fryer pot is not completely dry before filling 
with shortening. Refill the fryer pot with shortening ONLY when it is completely 
dry. 
 
17.  Dry the fryer pot and filter vat COMPLETELY. 
 
18.  Close the main drain and fill with new shortening to the proper level.