Bakers Pride LGF-F Manual De Usuario

Descargar
Página de 60
Gas Pressure Fryer 
 
Operation 
 
 
21 
Table 2. Product Programming Procedure 
 
STEP ACTION 
DISPLAY 
COMMENTS 
1 Press 
the 
FILTER/OFF/FRY 
switch to FRY
LOW  
Press PROG on the keypad. 
PROGRAM CODE
 
Input 1724 and press ENTER. 
PROGRAM PRODUCT #   
Select the program product 
number (1-8). 
PROGRAM PRODUCT X  X refers to the program number 
you selected. 
Press ENTER. 
PROGRAM TIME1 
00:00 
This command allows you to 
specify the cooking time for this 
stage. The time displayed may be 
a previously programmed value. 
Press TOGGLE/CLEAR and 
input the number of minutes you 
want to cook. 
PROGRAM TIME1 
XX:XX
XX:XX refers to the number of 
minutes you input. 
Press ENTER. 
PROGRAM TEMP1 
000 
°F 
This command allows you to 
specify the cooking temperature for 
this stage. The temperature 
displayed may be a previously 
programmed temperature. The 
temperature scale may also display 
°C depending on the system option 
that is set. 
Press TOGGLE/CLEAR and 
input the cooking temperature for 
product to be cooked. 
PROGRAM TEMP1 
XXX 
°F
XXX refers to the cooking 
temperature you input. 
Press ENTER. 
PROGRAM TEMPCOM1 
FLEX TIME
This command enables you to 
select whether or not time is 
allowed for the fryer to recover 
from temperature loss while 
cooking during this stage. The 
FLEX TIME option will allow the 
fryer to recover from temperature 
loss. 
10 
Press TOGGLE/CLEAR until the 
desired option is displayed. 
PROGRAM TEMPCOM1 
X
X refers to the temperature 
compensation option selected. 
11 
Press ENTER. 
PROGRAM VALVE1 
CLOSED 
This command allows you to 
specify whether the solenoid valve 
will be open or closed during this 
stage.  
12 
Press TOGGLE/CLEAR until the 
desired option is displayed. 
PROGRAM VALVE1 
X
X refers to the solenoid valve 
option selected. OPEN is used for 
Models ALF and BLF Automatic 
Lift 
fryers. If your program requires 
the solenoid valve to be closed 
while cooking, choose the 
CLOSED option.