ColdTech® Refrigerator Settings
Temperature set to 37 F
Parameter Function
Set Range
Default
E1
Lower Setpoint Limit
-40 F ~ set temp
36 F
E2
Higher Setpoint Limit
set temp ~ 120 F
45 F
E3
Hysteresis, temp. variance
1 ~ 18 F
10 F
E4
Comp. start delay time
0 ~ 10 min.
2 min.
E5
Offset on room temp
-5 ~ 5 F
0 F
E6
Offset on evap temp
-5 ~ 5 F
0 F
F1
Max. defrost duration
1 ~ 60 min.
N/A
F2
Defrost interval time
0 ~ 24 hr.
0
F3
Defrost termination temp
32 ~ 68 F
N/A
Applicable to Models:  J2GRF-40DT (refrigerator only), 
J3GRF-61DT (refrigerator only)
ColdTech® Freezer Merchandiser Settings
Temperature set to -10 F
Parameter Function
Set Range
Default
E1
Lower Setpoint Limit
-40 F ~ set temp
-20 F
E2
Higher Setpoint Limit
set temp ~ 120 F
20 F
E3
Hysteresis, temp variance
1 ~ 18 F
10 F
E4
Comp. start delay time
0 ~ 10 min.
3 min.
E5
Offset on room temp
-5 ~ 5 F
0 F
E6
Offset on evap temp
-5 ~ 5 F
0 F
F1
Max. defrost duration
1 ~ 60 min.
40 min.
F2
Defrost interval time
0 ~ 24 hr.
8 hr.
F3
Defrost termination temp
32 ~ 68 F
55 F
Key
F = Farenheit (degrees)
temp = temperature
min. = minutes
max = maximum
hr. = hours
N/A = not applicable
Warning:
Do not change the default settings of your ColdTech unit without consulting 
a qualified service technician or the ColdTech service department.
Applicable to Models:  J1GF-12S, J1GF-20S, J2GF-40S, 
J2GRF-40DT (freezer only), J3GF-61S, J3GRF-61DT (freezer only)