Instructions for the installer
 
 
24 
3.  OVEN INSTALLATION 
 
 
 
The oven must be set up on a perfectly flat surface and left standing 
free. Make sure to allow enough room at the back for easy access to the 
terminal strip for connecting the power supply cable. Installation must be 
carried out by a 
qualified technician in compliance with EEC 
DIRECTIVES currently in force. 
 
 
3.1 Electrical connection 
 
Make sure the voltage and the cross-section of the power cord match the 
specifications indicated on the identification plate positioned on the side of 
the oven. Do not remove this plate for any reason
The oven is fitted with an H07RN-F three-core cable for operation at 
230V
 and a power supply plug. 
 
 
 
 
 
The supplied cable is of the three-core 3 x 1.5 mm
2
 H07RN-F type.  
The power supply cable must be replaced by the manufacturer or by an 
authorised service centre to prevent any risks.
 
 
 
 
The terminal marked with this symbol connects parts together that are 
normally at zero potential. Connect the appliances appropriately using 
this terminal in order to make sure that they are equipotential. 
 
 
The plug and wall-mounted socket must be of the same type (in 
accordance with current regulations). Also check that the power supply 
line is provided with adequate earthing. Avoid use of adapters and 
shunts. 
 
3.1.1  Safety thermostat 
The oven is fitted with a safety device which trips in case of serious 
malfunction. To reset, contact the nearest technical assistance centre. 
 
 
 
 
The manufacturer declines all responsibility for damage to persons 
or things caused by the non-observance of the above prescriptions or 
deriving from tampering with any part of the appliance.