3.2  Burner and nozzle characteristics table 
 
 
 
Burner 
 
Rated 
heating 
capacity 
(kW) 
 
LPG
 
 
G30/G31
  
28/37
 
mbar
 
 
 
 
 
Nozzle 
diameter 
1/100 mm 
By-pass 
mm 
1/100 
Reduced  
flowrate 
(W) 
Flowrate  
g/h G30 
 
Flowrate  
g/h G31 
 
 
 
Auxiliary 
 
0.8 
50 
30 
350 
73  71 
 
 
 
Semi-rapid 
 
1.4 
65 
33 
450 
127  125 
 
 
 
Triple crown 
 
2.9 
95 
65 
1500 
233  229 
 
 
 
Oven 
 
3.0 
87 
48 
850 
233  229 
 
 
 
 
 
 
Burner 
 
Rated 
heating 
capacity 
(kW) 
 
TOWN GAS – G110 8 mbar 
 
 
 
 
Nozzle diameter 
1/100 mm 
Reduced Flowrate 
(W) 
 
 
 
Auxiliary 
 
0.8 
115 
350 
 
 
 
Semi-rapid 
 
1.4 
145 
450 
 
 
 
Triple crown 
 
2.9 
230 
1200 
 
 
 
Oven 
 
3.0 
225 
850 
 
 
 
 
   
Burner 
 
Rated 
heating 
capacity 
(kW) 
 
NATURAL GAS –
 
G20
  
20
 
mbar
 
 
 
 
 
Nozzle diameter 
1/100 mm 
Reduced Flowrate 
(W) 
 
 
 
Auxiliary 
 
1.0 
72 
350 
 
 
 
Semi-rapid 
 
1.7 
97 
450 
 
 
 
Triple crown 
 
2.9 
130 
1500 
 
 
 
Oven 
 
3.0 
130 
850