Installer Instructions 
 
9
 
 
  2.4.6
  Connection using a collapsible steel pipe (for all gas types) 
 
 
 
 
  This connection type can be used for both of the installation methods shown in 
figures "A" and "B" in chapter “2. INSTALLING THE APPLIANCE”. Only use 
collapsible steel pipes that meet the requirements of the regulations in force with a 
maximum length of 2 metres. 
Screw the end of collapsible pipe L onto external threaded ½” gas fitting B (ISO 
228-1), interposing seal C in between the two. 
Once the installation is completed, check for any leaks using a soapy water 
solution, never using flame.
 
 
 
 
 
 
3  ADAPTATION TO DIFFERENT GAS TYPES 
 
 
 
 
  Before carrying out any procedure, cut the electrical supply to the appliance. 
 
 
 
 
  The cooking range hob is set to use natural  gas G20/G25 (2E+) at a pressure of 20/25 mbars in 
cooking ranges with a large oven, and butane/propane gas  G30/G31 (3+) at a pressure of 28/37 
mbars in cooking ranges provided with a cylinder housing. Moreover, the guide eye of the hose must 
be replaced with the appropriate one provided. If other types of gas are used, the burner injectors 
must be replaced, then the minimum flame must be adjusted on the gas taps. To replace the 
injectors, follow the instructions set out below. 
 
   
 
 
3.1  Replacing the hob injectors 
 
 
 
 
 This process does not require the 
primary air supply to be adjusted. 
1.
  Remove the racks, take out all 
flame spreaders and caps; 
2.
  use a 7-mm tubular spanner to 
unscrew the burner injectors; 
3.
  replace the burner injectors 
according to the gas to be used 
and as described in paragraph 
“3.2/3.3 Tables of burner and 
injector characteristics”. 
4.
  Put the burners back into their 
housings correctly.