137 
8.11  IS15 Rudder 
Dimensions: ............................... See Figure 8-11 
Weight: ...................................... 225 grams 
Environmental Protection:......... IP56 from front, IP44 from rear 
Power requirement:  .................. 12/24 VDC, 70 mA (100 mA max with max 
lighting) 
Safe distance to compass:.......... 0.15 m (0.5 ft.) 
Temperature:    Operating: ........ –0 to +55°C (+32 to +130°F) 
Storage: ............................. –30 to +80°C (–22 to +176°F) 
Scale: ......................................... Full deflection adjustable for any h.o. angle 
between ±20° and ±45°. Divisions: Marking per 
each 1/8 of full deflection. Accuracy: ±2° of full 
scale deflection. 
Heading Display (Digital): ........ 0 to 359° 
Heading Resolution: .................. 1° 
Heading reference:..................... True or Magnetic North 
Heading Lock: ........................... Course and direction to steer on digital display 
Course to Steer: ......................... Settable on digital display 
Display Backlighting:................ Green color with seven levels plus Off 
Display Backlighting Control:... Two independent lighting banks or individual 
settings (bank 0) 
Inputs:    Rudder Angle: ............ 2-wire p.w.m. 
NMEA 0183, RSA 
Roblink (IS15 system) 
Compass heading: ...... NMEA 0183, HDG, HDM, HDT 
Outputs:  Rudder Angle:............ NMEA 0183, RSA, 5 Hz* 
Compass heading: ...... NMEA 0183, HDG 
Other:.......................... NMEA 0183 sentences according to IS15 
NMEA in/out table.