Simrad AP26 Manual De Usuario

Descargar
Página de 152
Simrad AP26 and AP27 Autopilots 
58
 
20221586B
 
3.10  Drive unit installation 
The relations between drive units, drive unit voltage, autopilot 
computer, drive performance and interface to the steering gear 
are shown in the tables below.  
Refer to the connecting diagram for the different drive units on 
page 60 onwards. 
Installation instruction for the drive units are found in the 
manual for the individual units. 
The maximum drive current capability of the AC10, AC20 and 
AC40 autopilot computers are different. Use the table below as 
reference and observe the notes on next page. 
HYDRAULIC PUMPS 
  
 
RAM 
CAPACITY 
    
MODEL MOTOR 
VOLTS 
AUTOPILO
COMPUTER 
 
MIN 
cm
(cu. in.) 
 
MAX 
cm
3
  
(cu. in.) 
FLOW RATE 
AT 10 bar 
cm
3
/min 
(cu. in/min) 
MAX 
PRESSURE 
bar 
PWR. 
CONSUM-
PTION 
RPU80 12V  AC10 80 
(4,9) 
250 
(15,2) 
800 (49) 
50 
2,5-6 A 
RPU160 12V  AC20 160 
(9,8)
550 
(33,5) 
1600 (98) 
60 
3-10 A 
RPU300 12V  AC40  290 
(17,7) 
960 
(58,5) 
3000 (183) 
60 
5-25 A 
RPU300 24V  AC20  290 
(17,7) 
960 
(58,5) 
3000 (183) 
60 
2,5-12 A 
Steering gear interface: Hydraulic plumbing 
Notes ! 
1.  The autopilot system detects whether a reversible motor or a 
solenoid is connected and outputs the correct drive signal 
automatically. 
2.  The drive output of AC10 is sufficient for any type of 12 and 
24V solenoids normally found on a recreational boat.