Graco 204490 Manual De Usuario

Descargar
Página de 20
Installation
306556S
5
Installation
Grounding
Pump: Use a ground wire and clamp as shown in 
Fig 1.
Air and fluid hoses: Use only electrically conductive 
hoses.
Air Compressor: Follow manufacturer’s recommen-
dations.
Spray fun and dispensing valve: Ground through 
connection to a properly grounded fluid hose and 
pump.
Fluid supply container: Follow your local code.
Truck bed or platform: Follow your local code.
Solvent pails used when flushing: Follow your local 
code. Use only metal pails, which are conductive, 
placed on a grounded surface. Do not place the pail 
on a nonconductive surface, such as paper or card-
board, which interrupts the grounding continuity.
To maintain grounding continuity when flushing or 
relieving pressure: 
Hold a metal part of the dispens-
ing valve firmly to the side of a grounded metal pail, 
then trigger the valve.
Grounding the Pump
1.
Remove the ground screw (Z) and insert through 
the eye of the ring terminal at the end of ground wire 
(Y).
2.
Fasten the ground screw back into the pump and 
tighten securely.
3.
Connect the other end of the ground wire to a true 
earth ground. (Fig 1).
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever 
you see this symbol.
1.
Close the pump’s air regulator.
2.
Close the supply pump’s bleed-type master air valve 
(required in this system).
3.
Hold a metal part of the dispensing valve firmly to a 
grounded metal waste container and open the dis-
pensing valve until pressure is fully relieved.
If you suspect that the dispensing valve, extension, or 
grease fitting coupler is clogged, or that pressure has 
not been fully relieved after following the steps above, 
VERY SLOWLY loosen the coupler or hose end cou-
pling and relieve pressure gradually, then loosen com-
pletely and clear the clog.
The equipment must be grounded to reduce the risk 
of static sparking and electric shock. Electric or static 
sparking can cause fumes to ignite or explode. 
Improper grounding can cause electric shock.  
Grounding provides an escape wire for the electric 
current.
F
IG
. 1
This equipment stays pressurized until pressure is 
manually relieved. To help prevent serious injury from 
pressurized fluid, such as skin injection, splashing 
fluid and moving parts, follow the Pressure Relief 
Procedure when you stop spraying and before 
cleaning, checking, or servicing the equipment.
Y
Z