Repair
General Repair Instructions
Before performing any repair procedures, relieve 
pressure
, page 2.
Pressure test distribution blocks yearly or every 
8000 hours. Replace seals and divider valves as 
necessary.
Purging Air From the System
Before machine operation is resumed following mainte-
nance or repair, manual system air purging must be per-
formed.
There are several air purging procedures available 
depending upon the maintenance or repair procedure.
NOTE: Use only clean oil filtered to the SAE -recom-
mended cleanliness level of ISO 18/14 (ISO Standard 
4406) when prefilling a system. The manufacturers of 
the machine tool and its component bearings should be 
consulted to ensure that the ISO 18/14 cleanliness level 
is adequate.
Page
Section
Air purging after:
8
1
Replacing line between a secondary divider valve and lube point.
9
2
Replacing a line between the master divider valve and a secondary 
divider valve.
3
Replacing a line between pump and master divider valve.
11
4
Adding or replacing any component in a master divider valve assembly.
5
Adding or replacing any component in module in a secondary divider 
valve assembly.