Cal Flame G3 Manual De Usuario

Descargar
Página de 28
8
Installation / 
Assemb
ly
2009 G3, G4, G5 Grills
LTR20091050, Rev. A
www.calspas.com
Natural Gas
Requirements
Always  check  the  rating  plate  to  make  sure  the  gas  supply  you  are 
hooking up to is the gas type the grill is manufactured for.
IMPORTANT: Never connect the grill to an unregulated gas supply.
The  installation  of  this  appliance  must  conform  with  local  codes  or, 
in  the  absence  of  local  codes,  to  the  national  fuel  gas  code,  ANSI 
Z223.1a-1998. Installation in Canada must be in accordance with the 
standard CAN/CGA-B149.2, Propane Installation Code.
A licensed contractor or local gas company representative must perform 
all natural gas connections.
Ensure that the service supplying the grill is fitted with a shut off valve 
conveniently positioned near the grill and giving ease of access.
The grill must be isolated from the gas supply piping system by closing 
its individual manual shutoff valve during any pressure testing of the 
gas supply piping system at test pressures equal to or less than 0.5 psi 
(3.5 kPa).
The grill and its individual shutoff valve must be disconnected from the 
gas supply piping system during any pressure testing of that system at 
test pressure in excess of 0.5 psi (3.5 kPa).
Your Cal Flame grill for use with natural gas comes equipped with its 
own regulator that MUST NOT be removed. If this regulator needs to be 
replaced, use only the type specified by Cal Flame for this appliance.
Connection
Remove the rear panel from the barbecue to gain access to the 
1. 
regulator and gas connection point.
Connect a suitable flex connector to the grill regulator.
2. 
Check the grill controls to ensure all control valves are in the full 
3. 
OFF position.
Turn on the main gas supply and check all connections for leaks 
4. 
using  soapy  water  as  described  in  the  leak  testing  procedure 
section.
Warning:  If  you  see  bubbles  in  the  soapy  solution  at  any  of  the 
connections,  turn  off  the  gas  supply  and  tighten  the  connection.  If 
tightening the connection does not seal the leak, it may be necessary 
to replace the flex hose.