Renesas SH7264 Manual De Usuario
![Renesas](https://files.manualsbrain.com/attachments/59153266feca598c11e08bf1f143ccfcf45441a4/common/fit/150/50/d3d06de51d338eb4f916b44a9629f9d48697a59cd7344be40cf24bae01c5/brand_logo.gif)
Section 19 Serial I/O with FIFO
Page 964 of 2108
R01UH0134EJ0400 Rev. 4.00
Sep
24,
2014
SH7262 Group, SH7264 Group
19.4.2
Serial Timing
(1) SIOFSYNC
The SIOFSYNC is a frame synchronous signal.
Figure 19.3 shows the SIOFSYNC synchronization timing.
SIOFSCK
SIOFRxD
SIOFTxD
SIOFSYNC
Start bit data
1-bit delay
1 frame
Figure 19.3 Serial Data Synchronization Timing