2. Check Direction of Gate Swing
The 4000XLS is designed for PULL-TO-OPEN installations. 
PUSH-TO-OPEN installations require a Push-To-Open Bracket 
 [R4KPTO]. Please refer to specific Push-To-Open Installation 
Information on page 21.  
4. Gate Grounding
  Shorter cable is better, 1 to 2 feet 
recommended.
  Bolt ring terminal at end of cable 
4 - 6 inches above ground level.
 
R4196 Kit Includes: 
u
 Ground Rod Clamp 
v
 6 AWG Wire (3 feet)
NOTE: No grounding system 
absolutely protects against 
lightning strikes. If installed 
correctly, a grounding system will 
help minimize damage to your  
gate opener.  
E
A
B
C
D
F
A – Level 
D – Posts Secured in Concrete
B – Plumb 
E – Centerline Mounting
C – Free Swinging 
F – Good Working Hinges
Horizontal Cross Member
Vertical Cross Member
Your Property
Your Property
Pull-To-Open
(arm retracts to open)
Push-To-Open
(arm extends to open)
3. Prepare the Gate
•  The gate must be plumb, level, and swing freely on its hinges.
•  The gate must move throughout its arc without binding or dragging on the ground.
•  Wheels must NOT be attached to the gate.
•  Gates over 250 lb. should have ball bearing hinges with grease fittings.
•  Post must be secured in the ground with concrete (minimizes twist/flex when the operator is
activated).
•  Make sure there is a stable area for mounting the gate bracket (this may require the addition of a
horizontal or vertical cross member). 
•  We recommend you position the operator near the center-line of the gate to keep the gate from
twisting and flexing, and to avoid back-splash from rain.
Metal Gate
Post
6  AWG Wire
8 Foot Ground Rod 
5/8” Copper Clad Steel (not included)
- available at local homecenter and hardware stores -
Ground Rod
Clamp