Technical Specifications
GTO/ACCESS SYSTEMS 4000XLS AUTOMATIC GATE OPERATOR
DRIVE
•  Low friction screw drive (linear actuator) rated for -5 ºF to +160 ºF (-21 ºC to +71 ºC). Use of GTO battery heater FM316
(Not solar compatible) is recommended in extreme cold temperatures. 
•  Powered by a 12 V motor with integral case hardened steel gear reducer. Motor speed reduced to 375 rpm.
•  Maximum opening arc of 110º. Approximate opening time (90º): 16-20 seconds, depending on weight of gate.
POWER
•  The system is powered by a 12 Vdc, 7.0 Ah, sealed, rechargeable acid battery.
•  Battery charge is maintained by a 120 Vac, 18 Vac output transformer. Blade-style control board fuse is rated for 25 A.
 
  NOTE: The transformer should not be directly connected to any battery. Do not replace fuses with higher ampere rated 
fuses; doing so will void your warranty and may damage your control board.
•  For optional solar charging see page 2.
CONTROL
•  GTO microprocessor-based control board is set for pull-to-open gate installations. DIP switches can be adjusted to
accommodate an optional kit for push-to-open gates (see Accessory Catalog).
•  A circuit on the control board regulates charging. “Sleep draw” is 25 mA; “active draw” is 5 to 9 A.
•  Auto-memorization of digital transmitter code.
•  GTO remote-mounted RF receiver tuned to 318 MHz.
•  Operator length with push-pull tube fully retracted is 46
1
/
4
”, mounting point to mounting point, arm stroke 22” max.
•  Minimum gate length is 6 ft.
•  Adjustable auto-close (3 to 120 seconds), and stall force potentiometers.
•  Power terminal block accommodates a transformer or solar panels (not both).
•  DIP switches simplify setup of gate operator.
•  Accessory terminal block fully compatible with GTO push button controls, digital keypads, loops detectors, etc.
•  Control board allows connection of safety edge sensors and photoelectric sensors.
•  Audio entrapment alarm sounds if unit encounters an obstruction twice while opening or closing.
OPERATIONAL CAPACITY
•  The Gate Capacity Chart shows approximate cycles, per day, you can expect from the 4000XLS Automatic Gate
Operators when powered with a transformer. Actual cycles may vary slightly depending upon the type and 
condition of gate and installation.
 
  NOTE: BALL BEARING HINGES SHOULD BE USED ON ALL GATES WEIGHING OVER 250 LB.
 
  To determine the number of cycles the gate operator will perform using solar panels, please see the specifications 
listed on page 2.
 
  * An operation cycle is one full opening and closing of the gate.
These specifications are subject to change without notice.
Gate Weight
Gate Length
GTO/ACCESS SYSTEMS 4000XLS Gate Capacity Chart     
Estimated number of daily cycles, based on use with a transformer and one(1) 12 Volt battery 
20 ft.
16 ft.
12 ft.
6 – 10 ft.
135
140
145
150
300 lb.
130
135
140
145
400 lb.
125
130
135
140
500 lb.
120
125
130
135
600 lb.
115
120
125
130
700 lb.
110
115
120
125
800 lb.
105
110
115
120
900 lb.
100
105
110
115
1000 lb.