  GTO 4000XLS Instruction Manual © 01.10.12  
13
IMPORTANT:
 •  The transformer is designed and intended for indoor use. If the transformer can only be
plugged into an outside electrical outlet, a weatherproof cover/housing (available at local 
electrical supply stores) must be used. 
 •  The only wire acceptable for use with GTO products is 16 gauge stranded, low voltage, direct
burial wire  [RB509]. This gauge enables the transformer to provide an adequate charge 
through the control board to the battery at distances up to 1000 ft.
 •  DO NOT use telephone wire or solid wire.
 •  NEVER SPLICE WIRES. Splicing permits corrosion and seriously degrades the wire’s ability to
carry an adequate current. 
 •  NEVER USE TRANSFORMER AND SOLAR PANEL(S) AT THE SAME TIME! Doing so will 
damage the control board. 
 •  If your gate is more than 1000 ft. from an AC power source, you will need to use at least 10
watts solar charging power  [FM122/FM123] to charge the battery. Refer to the Solar Panels 
and Gate Activity Chart on page 2.
Step 1
Make sure the control box power switch is OFF.
 
Step 2
Select the electrical outlet outlet into which you will plug the transformer. Measure the distance from this 
outlet to the control box following the path where the wire will be laid (allow for an additional 6” to be 
pulled into the control box).  
Step 3
Lay the low voltage wire in a trench following a path from 
the selected electrical outlet to the control box. Wires coming 
up from the ground should be run through PVC conduit to 
protect them from lawn mower blades, weed eaters, and 
grazing animals. Bury the wire in the trench.
Step 4 
Feed the low voltage wires upward through the strain relief 
opening on the lower left of the control box. Pull 6” to 8” of 
wire into the control box.
Connect the Power Input
ON/OFF Switch
ON/OFF
Power Cable from
Master Arm
Low Voltage Wire
from Transformer
or Solar Panel
PVC Pipe
GRN
COM COM
CY
CLE
CL
OSE
SAFET
Y
SHADO
W
LOOP
CL
OSE
EDGE
OPEN
EDGE
EXIT
OPEN
BLK
RECEIVER
RED
25
FUSE
BATT+
BATT-
1  2  3  4
ON    DIP
ORG
BLUE
WHT
GRN
BRN
RED
MASTER INPUTS
BLK
SOLAR
or
18 VAC
ORG
BLUE
WHT
GRN
BRN
RED
SLAVE INPUTS
BLK
LOCK
GTO
AUX