Cisco Systems 2960 Manual De Usuario

Descargar
Página de 1004
 
18-16
Catalyst 2960 and 2960-S Switch Software Configuration Guide
OL-8603-09
Chapter 18      Configuring Optional Spanning-Tree Features
Configuring Optional Spanning-Tree Features
Enabling UplinkFast for Use with Redundant Links
UplinkFast cannot be enabled on VLANs that have been configured with a switch priority. To enable 
UplinkFast on a VLAN with switch priority configured, first restore the switch priority on the VLAN to 
the default value by using the no spanning-tree vlan vlan-id priority global configuration command.
Note
When you enable UplinkFast, it affects all VLANs on the switch stack. You cannot configure UplinkFast 
on an individual VLAN.
You can configure the UplinkFast or the CSUF feature for rapid PVST+ or for the MSTP, but the feature 
remains disabled (inactive) until you change the spanning-tree mode to PVST+.
Beginning in privileged EXEC mode, follow these steps to enable UplinkFast and CSUF. This procedure 
is optional.
When UplinkFast is enabled, the switch priority of all VLANs is set to 49152. If you change the path 
cost to a value less than 3000 and you enable UplinkFast or UplinkFast is already enabled, the path cost 
of all interfaces and VLAN trunks is increased by 3000 (if you change the path cost to 3000 or above, 
the path cost is not altered). The changes to the switch priority and the path cost reduce the chance that 
a switch will become the root switch. 
When UplinkFast is disabled, the switch priorities of all VLANs and path costs of all interfaces are set 
to default values if you did not modify them from their defaults.
To return the update packet rate to the default setting, use the no spanning-tree uplinkfast 
max-update-rate
 global configuration command. To disable UplinkFast, use the no spanning-tree 
uplinkfast
 command.
Command
Purpose
Step 1
configure terminal
Enter global configuration mode.
Step 2
spanning-tree uplinkfast [max-update-rate 
pkts-per-second]
Enable UplinkFast.
(Optional) For pkts-per-second, the range is 0 to 32000 packets per 
second; the default is 150.
If you set the rate to 0, station-learning frames are not generated, 
and the spanning-tree topology converges more slowly after a loss 
of connectivity. 
When you enter this command, CSUF also is enabled on all 
nonstack port interfaces.
Step 3
end
Return to privileged EXEC mode.
Step 4
show spanning-tree summary
Verify your entries.
Step 5
copy running-config startup-config
(Optional) Save your entries in the configuration file.