Goodman Mfg 2- to 5-Tone Packaged Air Conditioner Manual De Usuario

Descargar
Página de 24
22
www.goodmanmfg.com
SS-GPC14H
SS-GPC14H
www.goodmanmfg.com
23
P
roduct
 S
PecificationS
P
roduct
 S
PecificationS
w
irinG
 d
iaGram
Wiring
is
subject
to
change.
Al
wa
ys
refer
to
the
wiring
diag
ram
or
the
unit
for
the
most
up-to-da
te
wiring
.
    
W
arning
High 
Voltage:
Disconnect
all
power
bef
or
e
ser
vicing
or
installing
this
unit.
Multiple
power
sour
ces
ma
y
be
pr
esent.
F
ailur
e
to
do
so
ma
y
cause
pr
operty
damage,
per
sonal
injur
y,
or
dea
th.

























T
HE
 G
O
O
DM
A

F
A
M
ILY
 O
F
C
O
MPAN
IES







®







































































































































































































6s




































2
3
NOTE #2
WH
NOTE #4
EM
TR
24V
208-240
3
CONTROL
240
208-240/1/60
SUPPLY VOLTAGE
C
COMP
C
S.A.
S
T1
R
L1
C
NOTE #4
H
F
RCCF
CM
T2
C
L2
BOX
H
RCCF
F
C
YL
BR
PU
2
24V
208
TR
C
BK
1
PU
COMP
CM
BR
BR
4
1
PLF
PU
BK
YL
S
BK
RD
BK
5
6
2
3
C R
LVJB
RD
BL
BR
WH
GR
YL
R
C
W2
W1
G
Y
A
T
O
T
S
M
R
E
H
T
T2
T1
RD
BL
NOTE #3
PU
BL
L1
GND
C
L2
PU
BK
60
/
/
1
0
4
2
-
8
0
2
7
8
9
BL
BR
208-240/1/60   0140G00407
RD
RD
BK
BK
RD
YL
C L G N
1 2 3
BL
BL
RD
RD
GR
GR
GR
EM
GR
SEE NOTE 2

1
L
3
1
2
R
W2
W1
Y
G
C
4
5
6
PLF
C
SEE NOTE #2
IF USED
THERMOSTAT
N
G
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION
COMPONENT LEGEND
C
CM
COMP
EM
GND
LVJB
PLF
RCCF
SA
TR
CONTACTOR
CONDENSER MOTOR
COMPRESSOR
EVAPORATOR MOTOR
EQUIPMENT GROUND
LOW VOLTAGE JUNCTION BOX
FEMALE PLUG / CONNECTOR
RUN CAPACITOR FOR
COMPRESSOR AND FAN
START ASSIST
TRANSFORMER
WIRE CODE
BK     BLACK
BL     BLUE
BR     BROWN
GR     GREEN
OR     ORANGE
PU     PURPLE
RD     RED
WH     WHITE
YL     YELLOW
FACTORY WIRING
          LINE VOLTAGE
          LOW VOLTAGE
          OPTINAL HIGH
          VOLTAGE
FIELD WIRING
          HIGH VOLTAGE
          LOW VOLTAGE
NOTES:
1.   REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS
      ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.
2.  TO CHANGE EVAPORATOR MOTOR SPEED MOVE WHITE AND YELLOW
     LEADS FROM EM "2" AND "3" TO "4" AND "5".  IF BOTH LEADS ARE
     ENERGIZED, THE HIGHER SPEED SETTING IS USED.
3.  FOR 208 VOLT TRANSFORMER OPERATION MOVE PURPLE WIRES
     FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
4.  START ASSIST FACTOR EQUIPED WHEN REQUIRED
5.  USE COPPER CONDUCTORS ONLY.
++  USE N.E.C. CLASS 2 WIRE
EM
1
C
2
3
SEE NOTE 5
YL
RD
SA
(IF USED) SEE NOTE 4
YL
WH
BK
PU
4 5
WH
WH
YL
BK


















































